• Optics and Precision Engineering
  • Vol. 21, Issue 8, 1974 (2013)
GAO Hong-zhi1,*, LU Qi-peng1, DING Hai-quan1, and CHEN Si-wei2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/ope.20132108.1974 Cite this Article
    GAO Hong-zhi, LU Qi-peng, DING Hai-quan, CHEN Si-wei. Improvement of model performance for near-infrared non-invasive biochemical analysis by pathlength correction space method[J]. Optics and Precision Engineering, 2013, 21(8): 1974 Copy Citation Text show less
    References

    [1] HEISE H M, MARBCH R.Multivariate determination of blood substrates in human plasma by FT-NIR spectroscopy[J].The International Society for Optical Engineering, 1991,1575: 507-508.

    [2] AMEROV A K, CHEN J, AMOLD M A.Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy [J].Analytical Chemistry, 2005,77: 4587-4594.

    [3] LUO Y H, CHEN ZH, CHEN X D, Detection limit of glucose concentration in noninvasive sensing with near infrared spectroscopy [J]. Opt. Precision Eng., 2008,16(5): 784-789. (in Chinese)

    [4] ALEXEEVA N V,ARNOLD M A.Impact of tissue heterogeneity on noninvasive near infrared glucose measurements in interstitial fluid of rat skin [J].Journal of Diabetes Science and Technology, 2010,4: 1041-1054.

    [5] LIU Z Y, PAN T. Equivalent waveband selection of VIS-NIR spectroscopic measurement for hemoglobin [J]. Opt. Precision Eng., 2012, 20(10): 2170-2175. (in Chinese)

    [7] CHEN X D. Possibility of noninvasive clinical biochemical examination by near infrared spectroscopy [J]. Opt. Precision Eng., 2008, 16(5): 759-763. (in Chinese)

    [8] CHEN X D, GAO J, DING H Q. Infrared spectroscopy for non-invasive blood glucose monitoring[J].Chinese Optics, 2012(4): 317-326.(in Chinese)

    [9] YAMAKOSHI K, YAMAKOSHI Y.Pulse glucometry: a new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometry [J].Journal of Biomedical Optics, 2006,11(5): 054028.

    [10] ZHANG ZH Y, MEN J L, LI G. Non-invasive measurement of human hemoglobin concentration by dynamic spectrum method [J]. Spectroscopy and Spectral Analysis, 2010, 30(1): 150-153.(in Chinese)

    [11] YANG Y, CHEN W L, SHI ZH ZH, et al.. Reference point of floating-reference method for blood glucose sensing [J]. Chinese Optics Letters,2010,8(4): 421-424.

    [12] DING H Q, LU Q P, GAO H ZH. Experimental study of differential spectum method for elimination of tissue background in noninvasive biochemical detection [J]. Spectroscopy and Spectral Analysis, 2012,32(9): 2347-2350. (in Chinese)

    [13] GAO H ZH, LU Q P, DING H Q. Study of calibration model of different pathlength spectra in near infrared noninvasive biochemical sensing[J]. Spectroscopy and Spectral Analysis, 2012, 32 (5): 1423-1426. (in Chinese)

    [14] LORBER A.Error propagation and figures of merit for quantification by solving matrix equations [J].Analytical Chemistry,1986, 58: 1167-1172.

    [15] LORBER A.Net analyte signal calculation in multivariate calibration [J].Analytical Chemistry,1997,69: 1620-1626.

    [16] OLESBERG J T, LIU L, ZEE V V, et al..In vivo near-infrared spectroscopy of rat skin tissue with varying blood glucose levels [J].Analytical Chemistry, 2006,78(1): 215-223

    [17] OLESBERG J T, AMOLD M A, HU S B.Temperature-insensitive near-infrared method for determination of protein concentration during protein crystal growth[J].Analytical Chemistry,2000,72(20): 4985-4990.

    [18] RILEY M R, ARNOLD M A, MURHAMMER D W.Effect of sample complexity on quantification of analytes aqueous samples by near-infrared spectroscopy [J].Applied Spectroscopy, 2000,54(2): 255-261.

    [19] LIU R, CHEN W L, GU X Y, et al.. Extraction of net analyte signal in the noninvasive blood glucose sensing [J].Nanotechnology and Precision Engineering, 2008,6(3): 207-211.(in Chinese)

    [20] ZHANG L, ZHANG CH P. Measurements of absorption and anisotropy coefficients in fat emulsion intralipid-10% [J].Chinese Journay of Luminescence, 2009, 30(6): 858-861.(in Chinese)

    [21] YANG H M, GAO H ZH, WANG D M, et al.. Study on determination of cholesterol and triglyceride in human serum utilizing Near-infrared water windows[C]. Proceedings of the 2nd Chinese Conference on Near Infrared Spectroscopy, 2008: 311-314. (in Chinese)

    [22] AMEROV A K, CHEN J, SMALL G W.Molar absorptivities of glucose and other biological molecules in aqueous solutions over the first overtone and combination regions of the near-infrared Spectrum[J].Applied Spectroscopy, 2004,58(10): 1195-1204.

    CLP Journals

    [1] LIU Jin, CAI Zi-jin, ZHANG Zi-yang, SUN Di, WANG Wen. Evaluation on noninvasive blood components measurement based on photolepthysmography[J]. Optics and Precision Engineering, 2016, 24(6): 1264

    GAO Hong-zhi, LU Qi-peng, DING Hai-quan, CHEN Si-wei. Improvement of model performance for near-infrared non-invasive biochemical analysis by pathlength correction space method[J]. Optics and Precision Engineering, 2013, 21(8): 1974
    Download Citation