• Optics and Precision Engineering
  • Vol. 18, Issue 6, 1303 (2010)
WANG Rui-rong1,2,*, CHEN Wei-min1, and WANG Wei2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: Cite this Article
    WANG Rui-rong, CHEN Wei-min, WANG Wei. Improvement of spectral resolution power for an elliptically curved crystal spectrometer[J]. Optics and Precision Engineering, 2010, 18(6): 1303 Copy Citation Text show less
    References

    [1] ANDERSON S G, HEETER R F, BOOTH R, et al..Broadband high-resolution elliptical crystal x-ray spectrometer for high energy density physics experiments [J].Rev.Sci.Instrum.2006,77:063115-1-5.

    [2] WANG R R, CHEN W M.Unfolded study on spectra by elliptical crystal spectrometer [J].Opt.Precision Eng.,2009,17(2):274-279.(in Chinese)

    [3] BARTIROMO R, GIANNELLA R, SPICELLA M L, et al..Time resolving beng crystal spectrometer for tokamak plasma diagnositic[J].Nuclear Instruments and Methods in Physics Research, 1984,225:378-384.

    [4] XIAO SH L, SHI J, LEI X M, et al..Characteristics and application of elliptical curved LiF crystal analyzer [J].Opt.Precision Eng., 2007, 15(6):824-828.(in Chinese)

    [5] BEIERSDORFER P, HENDERSON J R, KNAPP D A, et al..High-resolution x-ray spectrometer for an electron beam ion trap [J].Rev.Sci.Instrum,1990,61(9):2338-2342.

    [6] ZSCHORNACK G, MULLER G, MUSIOL G.Geometrical aberrations in curved bragg crystal spectrometer [J].Nuclear Instruments and Methods, 1982,200:481-490.

    [7] WANG R R.Research on key technologies of a window-type x-ray crystal spectrograph [D].Dissertation of Chongqing University, 2009:60-61.(in Chinese)

    [8] WANG R R, CHEN W M, DONG J Q, et al..High-resolution x-ray crystal spectrometer and its application in laser plasmas [J].Acta Optica Sinica, 2008,28 (6):1220-1224.(in Chinese)

    [9] XIONG X C, ZHONG X X, XIAO SH L, et al..Transmission efficiency of dual-channel elliptical crystal spectrometer [J].Opt.Precision Eng., 2002,10(6):592-596.(in Chinese)

    [10] HENKE B L, YAMADA H T , TANAKA T J, et al..Pulsed plasma source spectrometry in the 80-8 000 ev X-ray region [J].Rev.Sci.Instrum,1983,54(10):1311-1315.

    CLP Journals

    [1] WANG Rui-rong, WANG Wei. X-ray line profile measurements in laser produced plasma[J]. Collection Of theses on high power laser and plasma physics, 2014, 12(1): 1737

    [2] WANG Rui-rong. Calibration of integrated x-ray diffraction efficiency for elliptically curved quartz crystal[J]. Optics and Precision Engineering, 2017, 25(6): 1472

    WANG Rui-rong, CHEN Wei-min, WANG Wei. Improvement of spectral resolution power for an elliptically curved crystal spectrometer[J]. Optics and Precision Engineering, 2010, 18(6): 1303
    Download Citation