• Matter and Radiation at Extremes
  • Vol. 2, Issue 2, 69 (2017)
Yongsheng Li1、2、*, Chuanlei Zhai1, Guoli Ren1, Jianfa Gu1, Wenyi Huo1, Xujun Meng1, Wenhua Ye1、3, Ke Lan1、3、4, and Weiyan Zhang5
Author Affiliations
  • 1Institute of Applied Physics and Computational Mathematics, Beijing 100094, China
  • 2Graduate School, China Academy of Engineering Physics, Beijing 100088, China
  • 3Center for Applied Physics and Technology, Peking University, Beijing 100871, China
  • 4Collaborative Innovation Center of IFSA, Shanghai Jiao Tong University, Shanghai 200240, China
  • 5China Academy of Engineering Physics, Mianyang 621900, China
  • show less
    DOI: 10.1016/j.mre.2016.12.001 Cite this Article
    Yongsheng Li, Chuanlei Zhai, Guoli Ren, Jianfa Gu, Wenyi Huo, Xujun Meng, Wenhua Ye, Ke Lan, Weiyan Zhang. P2 asymmetry of Au's M-band flux and its smoothing effect due to high-Z ablator dopants[J]. Matter and Radiation at Extremes, 2017, 2(2): 69 Copy Citation Text show less

    Abstract

    X-ray drive asymmetry is one of the main seeds of low-mode implosion asymmetry that blocks further improvement of the nuclear performance of “high-foot” experiments on the National Ignition Facility [Miller et al., Nucl. Fusion 44, S228 (2004)]. More particularly, the P2 asymmetry of Au's M-band flux can also severely influence the implosion performance of ignition capsules [Li et al., Phys. Plasmas 23, 072705 (2016)]. Here we study the smoothing effect of mid- and/or high-Z dopants in ablator on Au's M-band flux asymmetries, by modeling and comparing the implosion processes of a Ge-doped ignition capsule and a Si-doped one driven by X-ray sources with P2 M-band flux asymmetry. As the results, (1) mid- or high-Z dopants absorb hard X-rays (M-band flux) and re-emit isotropically, which helps to smooth the asymmetric Mband flux arriving at the ablation front, therefore reducing the P2 asymmetries of the imploding shell and hot spot; (2) the smoothing effect of Ge-dopant is more remarkable than Si-dopant because its opacity in Au's M-band is higher than the latter's; and (3) placing the doped layer at a larger radius in ablator is more efficient. Applying this effect may not be a main measure to reduce the low-mode implosion asymmetry, but might be of significance in some critical situations such as inertial confinement fusion (ICF) experiments very near the performance cliffs of asymmetric X-ray drives.
    Yongsheng Li, Chuanlei Zhai, Guoli Ren, Jianfa Gu, Wenyi Huo, Xujun Meng, Wenhua Ye, Ke Lan, Weiyan Zhang. P2 asymmetry of Au's M-band flux and its smoothing effect due to high-Z ablator dopants[J]. Matter and Radiation at Extremes, 2017, 2(2): 69
    Download Citation