[1] LV Jia-yan, HE Ming-yuan CHEN Lin. Automated radiation calibration method based on Dunhuang radiometric calibration site[J]. Acta Optica Sinica, 2017, 37(8): 0801003.
[2] LIU En-chao, LI Xin, WEI Wei. Automatic field calibration and analysis of satillite based on hyper-spectral radio radiometer[J].Spectroscopy and Spectral Analysis, 2016, 36(12): 40776.
[3] LI Yuan, RONG Zhi-guo, ZHENG Zhao-jun. Post launch site calibration of visible and near-infrared channel of FY-3A visible and infrared radiometers[J].Optics and Precision Engineering, 2009, 17(12): 2966.
[5] CZAPLA-MYERS J S. Automated ground-based methodology in support of vicarious calibration[D]. Tucson: The University of Arizona, 2006: 41-43, 54-57.
[6] CZAPLA-MYERS J S, LESSON N P. Radiometric calibration of earth-oberving sensors using an automated test site at Railroad valley, Nevada[J]. Canadian Journal of Remote Sensing, 2010, 36(5): 474-487.
[7] WANG Ning, LI Chuan-rong. Ground based automated radiometric calibration system in Baotou site, China[C]. SPIE, 2017, 10427: 104271J.
[8] SCHMECHTIG C, SANTER R P, ROGER J C, et al. Automated ground-based station for vicarious calibration[C]. SPIE, 1997, 3221: 309-317.
[9] DANA X K, BRUEGGE C J. On-orbit calibration of the EO-1 hyperion and advanced land imager(ALI) sensors using the LED spectrometer(LSpec) automated facility[J]. IEEE Transactions on Geoscience and Remote Sensing, 2009, 47(4): 1244-1255.
[10] QIU Gang-gang, LI Xin, WEI Wei. Experiment and analysis of on-orbit radiometric calibration for remote sensors based on in-site automated observation technology[J]. Acta Optica Sinica, 2016, 36(7): 0701001.
[11] WEI Wei. Research on long time serice radiometric calibration of satellite sensor based on global calibration site network[D]. Hefei: University of Science and Technology of China, 2017: 1-10.
[12] DONG Yi, LV Jia-yan, SONG Qing-tao. Introduction to the principle and process of reflectivity basic radiation calibration technology innovation and application[J]. Technological Innovation and Application, 2016, 24, 71-72.
[13] University of Wyoming[DB/OL]. [2018-11-26].http: //weather.uwyo.edu/.
[14] NASA[DB/OL]. [2018-11-26].ftp: //toms.gsfc.nasa.gov/pub/omi/data/ozone/.
[16] WEI Wei, ZHANG Yan-na, ZHANG Meng. Multisite high-frequency radiometric calibration of GF-1 wide field of view[J]. Acta Photonica Sinica, 2018, 47(2): 0228001.
[17] YU Tang-qi, WEI Wei, ZHANG Yan-na. Analysis of the BRDF characteristics of Dunhuang radiometric calibration site in the spring[J]. Acta Photonica Sinica, 2018, 47(6): 0612004.
[18] WEI Wei, SONG Shuai. Development and application of automated vicarious calibration system [J]. Chinese Optics Letters, 2017, 15(10): 100101.
[19] QIU Gang-gang. Development and calibration applications of automatic observation system on satellite radiometric calibration site[D]. Hefei: University of Science and Technology of China, 2017: 28-34.
[20] SUN Ling, GUO Mao-hua, XU Na. On-orbit response variation of FY-3 MERSI reflective solar bands based on Dunhuang site calibration[J].Spectroscopy and Spectral Analysis, 2012, 32(7): 1870-1877.
[21] BIGGAR S F. In-flight methods for satellite sensor absolute radiometric calibration[D]. Tucson: University of Arizona, 1990: 142-145.
[22] ZHANG Yu-xiang, ZHANG Guang-shun, HUANG Yi-bin. In-flight vicarious radiometric calibration for VIS-NIR channels of FY-1C satellite sensor at Dunhuang site[J]. Acta Meteorologica Sinica, 2002, 60(6): 740-747.
[23] ZHANG Yu-xiang, QIU Kang-mu, HU Xiu-qing. Vicarious radiometric calibration of satellite FY-1D sensors at visible and near infrared channels[J].Acta Meteorologica Sinica, 2004, 18(4): 501-516.
[24] BIGGAR S F, SLATER P N, GELLMAN D I. Uncertainties in the in-flight calibration of sensors with reference to measured ground sites in the 0.4 to 1.1μm range[J]. Remote Sensing of Environment, 1994, 48: 245-252.