• Journal of Radiation Research and Radiation Processing
  • Vol. 40, Issue 5, 050601 (2022)
Weijiang BAI and Mai LU*
Author Affiliations
  • Key Laboratory of Opto-Electronic Technology and Intelligent Control, Ministry of Education, Lanzhou Jiaotong University, Lanzhou 730070, China
  • show less
    DOI: 10.11889/j.1000-3436.2022-0041 Cite this Article
    Weijiang BAI, Mai LU. Safety assessment of electromagnetic exposure of walk-through metal detectors operating at 6.48 kHz[J]. Journal of Radiation Research and Radiation Processing, 2022, 40(5): 050601 Copy Citation Text show less
    References

    [1] M Misakian, J P Casamento, B Laug. Development of emulator for walk-through metal detectors. IEEE Transactions on Electromagnetic Compatibility, 44, 486-489(2002).

    [2] D Wu, R Qiang, J Chen et al. Possible overexposure of pregnant women to emissions from a walk through metal detector. Physics in Medicine & Biology, 52, 5735-5748(2007).

    [3] C H Im, H K Jung. Numerical emulator for walk-through metal detectors using 3-D indirect boundary integral equation method. IEEE Transactions on Instrumentation & Measurement, 54, 1166-1170(2005).

    [4] N Orcutt, O P Gandhi. A 3-D impedance method to calculate power deposition in biological bodies subjected to time varying magnetic fields. IEEE transactions on bio-medical engineering, 35, 577(1988).

    [5] C Nelson, V Chaudhary, J Edman et al. Walk-through metal detectors for stadium security, 1-6(2016).

    [6] M Kato. Electromagnetics in Biology. Springer Berlin, 30, 149-150(2010).

    [7] Tao SONG, Xiaolin HUO, Shizeng WU. Bioelectromagnetic properties and their applications, 1-6(2008).

    [8] X L Chen, S Benkler, C H Li et al. Low frequency electromagnetic field exposure study with posable human body model, 2-5(2010).

    [9] D Poljak, M Cvetkovic, H Dodig et al. Electromagnetic-thermal analysis for human exposure to high frequency (HF) radiation. International Journal of Design & Nature and Ecodynamics, 12, 55-67(2017).

    [10] Jingcheng ZHOU, Yanyun LIN, Keliang CHEN et al. Effects of radiation-frequency electromagnetic radiation on cholinergic neuronal markers of SD rat brain. Journal of Radiation Research and Radiation Processing, 35, 010202(2017).

    [11] Min QU, Zhuoyue BI, Yumeng TANG et al. Application of bio-electromagnetic technique and its related health risk assessment strategy. High Voltage Engineering, 41, 2625-2634(2015).

    [12] C Gabriel, S Gabriel, E Corthout. The dielectric properties of biological tissues: I. Literature survey. Physics in Medicine & Biology, 41, 2231-49(1996).

    [13] S Gabriel, R W Lau, C Gabriel. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Physics in Medicine & Biology, 41, 2251-2269(1996).

    [14] S Gabriel, R W Lau, C Gabriel. The dielectric properties of biological tissues: III. Parametric models for the dielectric spec-trum of tissues. Physics in Medicine and Biology, 41, 2271-2293(1996).

    [15] V Korobsova, Y Morozov, M Stolorov. Influence of the electric field in 500 and 750 kV switchyards on maintenance staff and means for its protection, 23-26(1972).

    [16] Jiali BAO. Health effects of extremely low frequency electromagnetic fields. High Voltage Engineering, 41, 2550-2561(2015).

    [17] Qin WANG, Haifeng SU, Jiali BAO et al. Primary reaction for the environmental electric and magnetic fields exposure around High Voltage Transmission line on health effects. High Voltage Engineering, 39, 193-200(2013).

    [18] M Lu, S Ueno. Comparison of the induced fields using different coil configurations during deep transcranial magnetic stimulation. PLoS One, 12, e0178422(2017).

    [19] M Lu, S Ueno. Computational study toward deep transcranial magnetic stimulation using coaxial circular coils. IEEE Transactions on Biomedical Engineering, 62, 2911-2919(2015).

    [20] Dengpeng CHEN, Mai LU. Exposure characteristics of 5G mobile phone antenna and its temperature field distribution in the human head. Journal of Radiation Research and Radiation Processing, 39, 030601(2021).

    [21] Qingzhong DU, Mai LU. Safety assessment of electromagnetic exposure of quadruple-circuit AC transmission line with 1 000 kV/500 kV dual voltage on the same tower. Journal of Radiation Research and Radiation Processing, 38, 020602(2020).

    [22] G Z Editors, M Repacholi, A Mckinlay. International commission on non-ionizing radiation protection. Progress in Biophysics and Molecular Biology, 92, 1-3(2006).

    [27] Rui HUANG, Guoqiang ZENG, Qun LUO et al. Design of a weak signal processing circuit for metal security gates. Measurement and Control Technology, 33, 4(2014).

    Weijiang BAI, Mai LU. Safety assessment of electromagnetic exposure of walk-through metal detectors operating at 6.48 kHz[J]. Journal of Radiation Research and Radiation Processing, 2022, 40(5): 050601
    Download Citation