• Optical Instruments
  • Vol. 45, Issue 4, 40 (2023)
Liang SHEN, Shihong ZHU, and Xiuling LIANG*
Author Affiliations
  • Fujian Provincial Key Laboratory of Photonics Technology, Key Laboratory of Optoelectronic Science and Technology for Medicine (Ministry of Education), College of Photonic and Electronic Engineering, Fujian Normal University, Fuzhou 350007, China
  • show less
    DOI: 10.3969/j.issn.1005-5630.2023.004.006 Cite this Article
    Liang SHEN, Shihong ZHU, Xiuling LIANG. Design of a solar blind ultraviolet optical system for corona detection[J]. Optical Instruments, 2023, 45(4): 40 Copy Citation Text show less
    2D diagram of initial structure
    Fig. 1. 2D diagram of initial structure
    2D diagram of final structure
    Fig. 2. 2D diagram of final structure
    Spot diagram
    Fig. 3. Spot diagram
    MTF curves
    Fig. 4. MTF curves
    Diffraction encircled energy
    Fig. 5. Diffraction encircled energy
    Curves of distortion
    Fig. 6. Curves of distortion
    MTF curves at −20 ℃ and 60 ℃
    Fig. 7. MTF curves at −20 ℃ and 60 ℃
    Diagram of compensation structure
    Fig. 8. Diagram of compensation structure
    Actual compensation and ideal offset
    Fig. 9. Actual compensation and ideal offset
    MTF curves after compensation at −20 ℃ and 60 ℃
    Fig. 10. MTF curves after compensation at −20 ℃ and 60 ℃
    参数
    波长/nm240~280
    焦距/mm50
    相对孔径1/2.5
    靶面尺寸/mmΦ18
    MTF(@20 lp/mm) 畸变 ≥0.3 ≤3
    Table 1. Key design parameters of optical system
    温度/℃−20−100102030405060
    偏移量/mm−0.1313−0.0992−0.0665−0.033300.03460.06920.10430.1299
    Table 2. Ideal image plane offset at −20 -60 ℃
    表面 序号 半径公差 /光圈 厚度 公差/mm 表面偏心 公差/mm 元件偏心 公差/mm 元件倾斜 公差/° 表面不规 则度 折射率 公差 阿贝数 公差/%
    1±4±0.03±0.02±0.02±0.05±0.5±0.001±1
    2±4±0.03±0.02±0.5
    3±4±0.03±0.02±0.02±0.05±0.5±0.001±1
    4±4±0.03±0.02±0.5
    5±4±0.03±0.02±0.02±0.05±0.5±0.001±1
    6±4±0.03±0.02±0.5
    7±4±0.03±0.02±0.02±0.05±0.5±0.001±1
    8±4±0.03±0.02±0.5
    9±4±0.03±0.02±0.02±0.05±0.5±0.001±1
    10±4±0.03±0.02±0.5
    Table 3. Tolerance allocation of the system
    蒙特卡洛百分比/%MTF(@ 20 lp/mm)RMS光斑半径/mm
    ≥900.43910.0205
    ≥800.51180.0198
    ≥500.58240.0167
    ≥200.62550.0122
    ≥100.64940.0106
    Table 4. Results of Monte Carlo tolerance analysis