[1] Prakash S, Rana S, Prakash S et al. Automated collimation testing using a temporal phase shifting technique in Talbot interferometry[J]. Applied Optics, 47, 5938-5943(2008).
[2] Wang Y, Zhai H C, Jutamulia S et al. Collimation test of a corrected laser diode beam using lateral shearing interferometer[J]. Optics Communications, 274, 412-416(2007).
[3] Feng P, Tang F, Wang X Z et al. Dual-hole point diffraction interferometer for measuring the wavefront aberration of an imaging system[J]. Chinese Journal of Lasers, 48, 0904002(2021).
[4] Cordero-Davila A, Cornejo-Rodriguez A, Cardona-Nunez O. Null Hartmann and Ronchi-Hartmann tests[J]. Applied Optics, 29, 4618-4621(1990).
[5] Wu W, Luo Z R, Yu N H et al. Computer-aided alignment method based on Shack-Hartmann sensor[J]. Acta Optica Sinica, 41, 2022001(2021).
[6] Dong Y L, Wei C F, Liu X K et al. Measuring method of slit free-vortex aerodynamic window optical quality[J]. Chinese Journal of Lasers, 48, 2304003(2021).
[7] Hua Z Y, Xu C. The beam parallelism of large aperture collimator measured by scanning pentaprism method[J]. Optical Technique, 47, 582-586(2021).
[8] Yellowhair J, Burge J H. Analysis of a scanning pentaprism system for measurements of large flat mirrors[J]. Applied Optics, 46, 8466-8474(2007).
[9] Mohammadi K, Lee Y S, Jennewein T. Characterization of optical aberrations with scanning pentaprism for large collimators[C], ATh1D.6(2022).
[10] Liu Z D, Yu L N, Han Z G et al. Measurement of the wavefront collimation of a large aperture near-infrared interferometer using a scanning pentaprism system[J]. Chinese Journal of Lasers, 37, 1082-1087(2010).
[11] Tang Z X, Huang W, Xu W C et al. Application of differential pentaprism scanning in wavefront detection[J]. Chinese Optics, 7, 1003-1011(2014).
[12] Mallik P C V, Zhao C Y, Burge J H. Measurement of a 2-meter flat using a pentaprism scanning system[J]. Optical Engineering, 46, 023602(2007).
[13] Zhu X L, Wang D S, Nie F M et al. Large-aperture real-time compensated collimating wavefront error detection method[J]. Applied Sciences, 9, 2370(2019).
[14] Qi E H, Luo X, Zheng L G et al. Optical testing of large optical flat mirror with non-circular pupil based on scanning pentaprism technology[J]. Journal of Optoelectronics·Laser, 25, 1370-1375(2014).
[15] Yuan L, Zhang X H. Surface shape measurement of large flat mirrors using a scanning pentaprism method[J]. Chinese Optics, 12, 921-932(2019).
[16] Qi E H, Hu H X, Luo X. Study on low-order aberration measurements of large-aperture flats based on scanning pentaprism technology[J]. Applied Optics, 58, 787-793(2019).
[17] Wang X K, Qi E H, Hu H X et al. Optical testing of the super-large plane mirror (Invited)[J]. Infrared and Laser Engineering, 51, 20210953(2022).
[18] Chang S, Cao Y P, Chen Y Q. Kinematic error effect of pentagonal prism on wavefront measurement[J]. Optical Instruments, 27, 12-16(2005).
[19] Tenjimbayashi K. Straightness measurement of a moving table by using laser beams[J]. Proceedings of SPIE, 4093, 47-57(2000).
[20] Hsieh T H, Chen P Y, Jywe W Y et al. A geometric error measurement system for linear guideway assembly and calibration[J]. Applied Sciences, 9, 574(2019).