• Optics and Precision Engineering
  • Vol. 23, Issue 1, 197 (2015)
GUO Tian-tai1,*, WANG Xiao-xiao1, HONG Bo1, KONG Ming1, and SHI Yu-shu2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/ope.20152301.0197 Cite this Article
    GUO Tian-tai, WANG Xiao-xiao, HONG Bo, KONG Ming, SHI Yu-shu. Self-calibration technology in measuring error separation of imaging instrument[J]. Optics and Precision Engineering, 2015, 23(1): 197 Copy Citation Text show less
    References

    [1] WANG X ZH, CHEN ZH J, LI J F. Research on test errors ofImage measuring instrument [J]. Machine Tool & Hydraulics, 2009, 37(11):117-119. (in Chinese)

    [2] XIE H K. The Development and comments of image measureing instrument [J].Tool Engineering, 2011, 45(8):3-7. (in Chinese)

    [3] ZOU H D, ZHU L R, TAO W Y. Precise calibration methods development and ITS application on vision measuring system [J].Computer Measurement & Control, 2010, 18(9):2057-2059. (in Chinese)

    [4] XIE SH B. The uncertainty analysis for measurement of Image measuring instrument [J]. Industrial Measurement, 2012, 22(1):39-40. (in Chinese)

    [5] ZHU L W, ZHU Y, YI W SH. Quantitive evaluation of the uncertainty of self-calibration for ultra-precision stages [J].J Tsinghua Univ(Sci&Tech), 2006, 46(8): 1384-1387. (in Chinese)

    [6] ZHU Y, ZHU L W, YIN W SH, et al.. Research on self-calibration of ultra-precision stages applied in IC fabrication and inspection devices [J].Equipment for Electronic Products Manufacturing, 2005, 34(3): 20-24. (in Chinese)

    [7] ZHU L W, ZHU Y, YIN W SH. Research on self- calibration of two- dimensional ultra- precision stages [J]. China Mechanical Engineering, 2005, 16(20): 1787-1890. (in Chinese)

    [8] WANG D D, ZOU H, GUO T T, et al..Error measurement technique for two-dimensional stage of three-coordinate measuring machine based on self-calibration algorithm [J]. Chinese Journal of Scientific Instrument, 2013, 34(11): 2451-2457. (in Chinese)

    [9] DANG Q C, YOO S. KIM S W. Complete 3-D self-calibration of coordinate measuring machines [J]. CIRP Annals Manufacturing Technology, 2006, 55(1): 527-530.

    [10] YOO S, KIM S W. Self-calibration algorithm for testing out-of-plane errors of two-dimensional profiling stages [J].International Journal of Machine Tools and Manufacture, 2004, 44(8): 767-774.

    [11] RAUGH M R. Absolute two-dimensional sub-micron metrology for electron beam lithograph [J]. Precision Engineering, 1985, 7(1): 3-13.

    [12] TAKAC M. Self-calibration in two dimensions [J]. Technical Report, 1994, 2725:130-146.

    [13] YE J, TAKAC M, BERGLUND C N, et al.. An exact algorithm for self-calibration of precision metrology stages [J]. Precision Engineering, 1997, 20(1):16-32.

    [14] LU X M, TRAN H D. Self-calibration for 2-dimensional precision stages based on circle closure principle [J]. Proceedings of the Annual Meeting-American Society for Precision Engineering, 2000:548-552.

    [15] ZHU Y, HU C X, HU J CH. Least-square Based Self-calibration of Two-dimensional Ultra-precision Stages [C]. 2011 International Conference on Mechatronics and Automation (ICMA), 2011, 978(1): 597-602.

    [16] ZHU Y, HU CH X, HU J CH. A transitive algorithm for self-calibration of two-dimensional ultra-precision stages [J]. International Conference on Advanced Intelligent Mechatronics, 2011, 978(8):594-598.

    [17] ZHU Y, HU CH X, HU J CH, et al.. Accuracy and simplicity oriented self-calibration approach for two-dimensional precision stages [J]. Transactions on industrial electronics, 2013, 60(6): 2264-2272.

    [18] HU CH X, ZHU Y, HU J CH, et al..A holistic self-calibration approach for determination of three-dimensional stage error [J]. Transactions on Instrumentation and Measurement, 2013, 62(2): 483-494.

    [19] CUI J W, LIU X M, TAN J B. Self-calibration for 2-D ultra-precision stage [J].Opt. Precision Eng., 2012, 20(9): 1960-1966. (in Chinese)

    [20] GUO T T, WANG X X, ZOU H, et al.. Application of self-calibration in flatness assessment [J]. Advanced Materials Research, 2012(605):1054-1057.

    CLP Journals

    [1] GUO Xian-tao, HUANG Teng, SHENG Yue-qian. Self-calibration of terrestrial laser scanner based on stochastic inner constraint information of estimated parameters[J]. Optics and Precision Engineering, 2016, 24(6): 1319

    GUO Tian-tai, WANG Xiao-xiao, HONG Bo, KONG Ming, SHI Yu-shu. Self-calibration technology in measuring error separation of imaging instrument[J]. Optics and Precision Engineering, 2015, 23(1): 197
    Download Citation