• Acta Photonica Sinica
  • Vol. 49, Issue 7, 725001 (2020)
Ke-fei SONG1, Zhen-wei HAN1、2、*, Ling-ping HE1, and Qi-liang NI1
Author Affiliations
  • 1Changchun Institute of Optics Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/gzxb20204907.0725001 Cite this Article
    Ke-fei SONG, Zhen-wei HAN, Ling-ping HE, Qi-liang NI. Inductive Charge Readout for Far Ultraviolet Photon Count Imaging Detector[J]. Acta Photonica Sinica, 2020, 49(7): 725001 Copy Citation Text show less
    References

    [1] MCCOY R P. Space weather comes of agenew senss models f ionospheric specification fecast[C]. SPIE, 2004, 5548: 341347.

    [3] , P ROBERT. Special sensor ultraviolet limb imager:an ionospheric and neutral density profiler for the defense meteorological satellite program satellites. Optical Engineering, 33, 423-429(1994).

    [4] THONNARD S E, BUDZIEN S A, NICHOLAS A C, et al. Update on the calibration perfmance of the special sens ultraviolet limb imagers (SSULI)[C]. Spies International Symposium on Optical Science, 1999, 3818: 9098.

    [5] LEW P H, MABRY D J, GOLDSTEN J O, et al. Design perfmance of the Global Ultraviolet Imager (GUVI)[C]. SPIE, 1998, 3445: 212.

    [8] J S LAPINGTON. A comparison of readout techniques for high-resolution imaging with microchannel plate detectors. Nuclear Instruments & Methods in Physics Research, Section A:Accelerators, Spectrometers, Detectors and Associated Equipment, 525, 361-365(2004).

    [9] O JAGUTZKI, J S LAPINGTON, L B C WORTH. Position sensitive anodes for MCP read-out using induced charge measurement. Nuclear Instruments & Methods in Physics Research, Section A:Accelerators, Spectrometers, Detectors and Associated Equipment, 477, 256-261(2002).

    [12] B B WIGGINS, Z O SOUZA, J VADAS. Achieving high spatial resolution using a microchannel plate detector with an economic and scalable approach. Nuclear Instruments & Methods in Physics Research, Section A:Accelerators, Spectrometers, Detectors and Associated Equipment, 872, 144-149(2017).

    [13] B B WIGGINS, E RICHARDSON, D SIWAL. Optimizing the position resolution of a Z-stack microchannel plate resistive anode detector for low intensity signals. Review of Scientific Instruments, 86, 0833031-0833037(2015).

    [17] L SCHWARZ. The design and manufacture of wedge and strip anodes. IEEE Transactions on Nuclear Science, 33, 288-292(2007).

    [20] P L RAJBHANDARY, N J PELC. Effect of electronic noise and lowest energy threshold selection in photon counting detectors. Physics of Medical Imaging, 3, 178-187(2018).

    Ke-fei SONG, Zhen-wei HAN, Ling-ping HE, Qi-liang NI. Inductive Charge Readout for Far Ultraviolet Photon Count Imaging Detector[J]. Acta Photonica Sinica, 2020, 49(7): 725001
    Download Citation