• Chinese Optics Letters
  • Vol. 8, Issue 1, 33 (2010)
Haihua Cui, Wenhe Liao, Xiaosheng Cheng, Ning Dai, and Tianran Yuan
Author Affiliations
  • College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
  • show less
    DOI: 10.3788/COL20100801.0033 Cite this Article Set citation alerts
    Haihua Cui, Wenhe Liao, Xiaosheng Cheng, Ning Dai, Tianran Yuan. A three-step system calibration procedure with error compensation for 3D shape measurement[J]. Chinese Optics Letters, 2010, 8(1): 33 Copy Citation Text show less

    Abstract

    System calibration, which usually involves complicated and time-consuming procedures, is crucial for any three-dimensional (3D) shape measurement system based on vision. A novel improved method is proposed for accurate calibration of such a measurement system. The system accuracy is improved with considering the nonlinear measurement error created by the difference between the system model and real measurement environment. We use Levenberg-Marquardt optimization algorithm to compensate the error and get a good result. The improved method has a 50% improvement of re-projection accuracy compared with our previous method. The measurement accuracy is maintained well within 1.5% of the overall measurement depth range.
    Haihua Cui, Wenhe Liao, Xiaosheng Cheng, Ning Dai, Tianran Yuan. A three-step system calibration procedure with error compensation for 3D shape measurement[J]. Chinese Optics Letters, 2010, 8(1): 33
    Download Citation