• Chinese Journal of Lasers
  • Vol. 46, Issue 4, 0404002 (2019)
Qiaofeng Zhang1、*, Jinlin Xie1、*, Feibin Fan2, Longlong Sang2, Weixing Ding2, and Quanming Lu2
Author Affiliations
  • 1 Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui 230026, China
  • 2 CAS Key Laboratory of Geoscience Environment, School of Earth and Space Sciences, University of Science and Technology of China, Hefei, Anhui 230026, China
  • show less
    DOI: 10.3788/CJL201946.0404002 Cite this Article Set citation alerts
    Qiaofeng Zhang, Jinlin Xie, Feibin Fan, Longlong Sang, Weixing Ding, Quanming Lu. Linewidth Narrowing and Measurement of Pulsed Dye Laser[J]. Chinese Journal of Lasers, 2019, 46(4): 0404002 Copy Citation Text show less
    Schematic of external cavity narrowing linewidth system and LIF diagnostic system composed of pulsed dye laser
    Fig. 1. Schematic of external cavity narrowing linewidth system and LIF diagnostic system composed of pulsed dye laser
    Experiment schematic of F-P etalon photographing method
    Fig. 2. Experiment schematic of F-P etalon photographing method
    Laser output line types after using F-P etalon. (a) Multimode output (laser detuning); (b) single-mode output
    Fig. 3. Laser output line types after using F-P etalon. (a) Multimode output (laser detuning); (b) single-mode output
    Linewidth of dye laser measured by F-P interferometer
    Fig. 4. Linewidth of dye laser measured by F-P interferometer
    Narrow laser linewidth test for parallel-planar cavity F-P interferometer. (a) Schematic of plane-parallel cavity; (b) results of linewidth narrowing test
    Fig. 5. Narrow laser linewidth test for parallel-planar cavity F-P interferometer. (a) Schematic of plane-parallel cavity; (b) results of linewidth narrowing test
    Schematic of wavelength calibration experiment
    Fig. 6. Schematic of wavelength calibration experiment
    Comparison of two wavelength tuning methods. (a) Only F-P interferometer scanning; (b) dye laser and F-P interferometer scanning
    Fig. 7. Comparison of two wavelength tuning methods. (a) Only F-P interferometer scanning; (b) dye laser and F-P interferometer scanning
    LIF diagnostic system measurement results. (a) Original laser (4 GHz); (b) narrowed laser (340 MHz)
    Fig. 8. LIF diagnostic system measurement results. (a) Original laser (4 GHz); (b) narrowed laser (340 MHz)
    Qiaofeng Zhang, Jinlin Xie, Feibin Fan, Longlong Sang, Weixing Ding, Quanming Lu. Linewidth Narrowing and Measurement of Pulsed Dye Laser[J]. Chinese Journal of Lasers, 2019, 46(4): 0404002
    Download Citation