• Acta Photonica Sinica
  • Vol. 41, Issue 7, 781 (2012)
ZHANG Mei1,*, LIN Lin2, GAO Yingjun3, and LUO Yunhan3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3788/gzxb20124107.0781 Cite this Article
    ZHANG Mei, LIN Lin, GAO Yingjun, LUO Yunhan. Reverse Calculation of Optical Parameters of Scattering Medium Based on Fast Monte Carlo Simulation[J]. Acta Photonica Sinica, 2012, 41(7): 781 Copy Citation Text show less
    References

    [1] BOHREN C F, HUFFMAN D R. Absorption and scattering of light by small particles[M].New York: John Wiley and Sons, 1983: 99136.

    [2] FANG Q, BOAS D A. Monte Carlo simulation of photon migration in 3D turbid media accelerated by graphics processing units[J]. Optics Express, 2009, 17(22): 2017820190.

    [3] CHEN C, LU J Q, DING H, et al. A primary method for determination of optical parameters of turbid samples and application to Intralipid between 550 and 1630 nm[J]. Optics Express, 2006, 14(16): 74207435.

    [4] TYCHO A, JOGENSEN T M, YURA H T, et al. Derivation of a Monte Carlo method for modeling heterodyne detection in optical coherence tomography systems[J]. Applied Optics, 2002, 41(31): 66766691.

    [5] ALERSTAM E, SVENSSON T, ENGELS S A. Parallel computing with graphics processing units for highspeed Monte Carlo simulation of photon migration[J]. Journal of Biomedical Optics Letters, 2008, 13(6): 06050410605043.

    [6] WILSON B C. A Monte Carlo model for the absorption and flux distributions of light in tissue[J]. Medical Physics, 1983, 10(6): 824830.

    [7] YUN T, ZENG N, LI W, et al. Monte Carlo simulation of polarized photon scattering in anisotropic media[J]. Optics Express, 2009, 17(19): 1659016602.

    [8] GRAAFF R, KOELINK M H, de MUL F F, et al. Condensed Monte Carlo simulations for the description of light transport[J]. Applied Optics, 1993, 32(4): 426434.

    [9] LIU Q, RAMANUJAM N. Scaling method for fast Monte Carlo simulation of diffuse reflectance spectra from multilayered turbid media[J]. JOSA A, 2007, 24(4): 10111025.

    [10] WANG L H, JACQUES S L, ZHENG L Q. MCMLMonte Carlo modeling of light transport in multilayered tissues[J]. Comput Methods Programs Biomed, 1995, 47(2): 131146.

    [11] LIN Lin, ZHANG Mei, ZHANG Huailing. Numerical simulation of focused optical beam in tissue samples[J]. Chinese Journal of Medical Imaging Technology, 2010, 26(12): 23752378.

    CLP Journals

    [1] LIN Lin, ZHANG Mei. Low-coherence measurement of glucose concentration in solution based on inverse Monte Carlo method[J]. Optics and Precision Engineering, 2013, 21(9): 2231

    ZHANG Mei, LIN Lin, GAO Yingjun, LUO Yunhan. Reverse Calculation of Optical Parameters of Scattering Medium Based on Fast Monte Carlo Simulation[J]. Acta Photonica Sinica, 2012, 41(7): 781
    Download Citation