• Chinese Optics Letters
  • Vol. 2, Issue 11, 11658 (2004)
Yuanli Cheng1、*, Yongpeng Zhao1, Qi Wang1, Taniguch d2, Y. Hayashi2, and E. Hotta2
Author Affiliations
  • 1National Key Laboratory of Tunable Laser Technology, Harbin Institute of Technology, Harbin 150001
  • 2Department of Energy Sciences, Tokyo Institute of Technology, Tokyo, Japan
  • show less
    DOI: Cite this Article Set citation alerts
    Yuanli Cheng, Yongpeng Zhao, Qi Wang, Taniguch d, Y. Hayashi, E. Hotta. Soft X-ray amplification in 3- and 4-mm-diameter capillaries[J]. Chinese Optics Letters, 2004, 2(11): 11658 Copy Citation Text show less

    Abstract

    Laser pulses with energy of ~10 μJ are generated at 46.9 nm on the 3p-3s transition of the Ne-like Ar by a fast capillary discharge setup in both 3- and 4-mm channels. The dependence of the laser output pulse energy on the pressure of Ar gas is measured for 3-mm-diameter capillaries at currents of 25, 30, and 35 kA. Under the same discharge conditions used in 3-mm capillaries, experiments indicate that higher and faster current pulses are required to produce soft X-ray amplification in 4-mm-diamater capillaries.
    Yuanli Cheng, Yongpeng Zhao, Qi Wang, Taniguch d, Y. Hayashi, E. Hotta. Soft X-ray amplification in 3- and 4-mm-diameter capillaries[J]. Chinese Optics Letters, 2004, 2(11): 11658
    Download Citation