• Journal of Innovative Optical Health Sciences
  • Vol. 10, Issue 3, 1750005 (2017)
Haibo Zhang1, Guohua Geng1、*, Yanrong Chen1, Fengjun Zhao1, Yuqing Hou1, Huangjian Yi1, Shunli Zhang1, Jingjing Yu2, and Xiaowei He1
Author Affiliations
  • 1School of Information Sciences and Technology, Northwest University, Xi'an, Shannxi 710027, P. R. China
  • 2School of Physics and Information Technology, Shaanxi Normal University, Xi'an, Shannxi 710062, P. R. China
  • show less
    DOI: 10.1142/s1793545817500055 Cite this Article
    Haibo Zhang, Guohua Geng, Yanrong Chen, Fengjun Zhao, Yuqing Hou, Huangjian Yi, Shunli Zhang, Jingjing Yu, Xiaowei He. Performance evaluation of the simplified spherical harmonics approximation for cone-beam X-ray luminescence computed tomography imaging[J]. Journal of Innovative Optical Health Sciences, 2017, 10(3): 1750005 Copy Citation Text show less

    Abstract

    As an emerging molecular imaging modality, cone-beam X-ray luminescence computed tomography (CB-XLCT) uses X-ray-excitable probes to produce near-infrared (NIR) luminescence and then reconstructs three-dimensional (3D) distribution of the probes from surface measurements. A proper photon-transportation model is critical to accuracy of XLCT. Here, we presented a systematic comparison between the common-used Monte Carlo model and simplified spherical harmonics (SPN). The performance of the two methods was evaluated over several main spectrums using a known XLCT material. We designed both a global measurement based on the cosine similarity and a locally-averaged relative error, to quantitatively assess these methods. The results show that the SP3 could reach a good balance between the modeling accuracy and computational e±ciency for all of the tested emission spectrums. Besides, the SP1 (which is equivalent to the diffusion equation (DE)) can be a reasonable alternative model for emission wavelength over 692 nm. In vivo experiment further demonstrates the reconstruction performance of the SP3 and DE. This study would provide a valuable guidance for modeling the photon-transportation in CB-XLCT.
    Haibo Zhang, Guohua Geng, Yanrong Chen, Fengjun Zhao, Yuqing Hou, Huangjian Yi, Shunli Zhang, Jingjing Yu, Xiaowei He. Performance evaluation of the simplified spherical harmonics approximation for cone-beam X-ray luminescence computed tomography imaging[J]. Journal of Innovative Optical Health Sciences, 2017, 10(3): 1750005
    Download Citation