• Chinese Journal of Lasers
  • Vol. 43, Issue 1, 102004 (2016)
Xu Dan1、2、*, Lu Bin1、2, Yang Fei1, Chen Dijun1, Cai Haiwen1, and Qu Ronghui1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/cjl201643.0102004 Cite this Article Set citation alerts
    Xu Dan, Lu Bin, Yang Fei, Chen Dijun, Cai Haiwen, Qu Ronghui. Narrow Linewidth Single-Frequency Laser Noise Measurement Based on a 3×3 Fiber Coupler[J]. Chinese Journal of Lasers, 2016, 43(1): 102004 Copy Citation Text show less
    References

    [1] F Lienhart, S Boussen, O Carraz, et al.. Compact and robust laser system for rubidium laser cooling based on the frequency doubling of a fiber bench at 1560 nm[J]. Applied Physics B: Lasers and Optics, 2007, 89(2-3): 177-180.

    [2] G A Cranch, G M H Flockhart, C K Kirkendall. Distributed feedback fiber laser strain sensors[J]. IEEE Sensors Journal, 2008, 8(7-8): 1161-1172.

    [5] J P Cariou, B Augere, M Valla. Laser source requirements for coherent lidars based on fiber technology[J]. Comptes Rendus Physique, 2006, 7(2): 213-223.

    [6] F Yang, Q Ye, Z Pan, et al.. 100-mW linear polarization single-frequency all-fiber seed laser for coherent Doppler lidar application[J]. Opt Commun, 2012, 285(2): 149-152.

    [8] Takakura T, Iga K, Tako T. Line- width measurement of a single longitudinal mode AlGaAs laser with a Fabry- Perot interferometer[J]. Japanese Journal of Applied Physics, 1980, 19(12): 1468-1488.

    [10] T Okoshi, K Kikuchi, A Nakayama, et al.. Novel methed for high resolution measurement of laser output spectrum[J]. Electron Lett, 1980, 16(16): 630-631.

    [11] L Richter, H I Mandelberg, M Kruger, et al.. Linewidth determination from self-heterodyne measurement with subcoherence delay times[J]. IEEE Journal of Quantum Electronics, 1986, 22(11): 2070-2074.

    [15] H Tsuchida. Simple technique for improving the resolution of the delayed self-heterodyne method[J]. Opt Lett, 1990, 15(11): 640-642.

    [16] J W Dawson, Namkyoo Park, K J Vahala. An improved delayed self-heterodyne interferometer for linewidth measurements [J]. IEEE Photonics Technology Letters, 1992, 40(9): 1063-1066.

    [17] H Tsuchida. Laser frequency modulation noise measurement by recirculating delayed self-heterodyne method[J]. Opt Lett, 2011, 36(5): 681-683.

    [18] Cao Chunyan, Yao Qiong, Rao Wei, et al.. Linewidth measurement using unbalanced fiber-optic interferometer for narrow linewidth lasers[J]. Chinese J Lasers, 2011, 38(5): 0508005.

    [20] P D Welch. The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms[J]. IEEE Transactions on Audio and Electroacoustics, 1967, 15(2): 70-73.

    [21] R P Scott, C Langrock, B H Kolner. High-dynamic-range laser amplitude and phase noise measurement techniques[J]. IEEE Journal of Selected Topics in Quantum Electronics, 2001, 7(4): 641-655.

    [22] G D Domenico, S Schilt, P Thomann. Simple approach to the relation between laser frequency noise and laser line shape [J]. Appl Opt, 2010, 49(25): 4801-4807.

    [23] Y Takushima, H Y Choi, Y C Chung. Measurement of differential phasor diagram of multilevel DPSK signals by using an adjustment-free delay interferometer composed of a 3×3 optical coupler[J]. J Lightwave Technol, 2009, 27(6): 718-730.

    CLP Journals

    [1] TAN Jun, MU Chun-yuan, WANG Yue-hui, YU Hai-yang, ZHAO Ze-ping, CHEN Wei, LIU Jian-guo, ZHU Ning-hua. High Stability Four-lane Integrated Laser Module with Different Frequency in the Same Spectrum[J]. Acta Photonica Sinica, 2018, 47(4): 414001

    [2] Sun Junjie, Wang Zefeng, Wang Meng, Cao Jianqiu, Chen Jinbao. Narrow Linewidth Erbium-Doped Fiber Laser with a π Phase-Shifted Fiber Bragg Grating[J]. Laser & Optoelectronics Progress, 2017, 54(8): 81406

    [3] Wang Ping, Chen Jian, You Xiaodi, Ma Zhaohui, Liu Xue, Yu Changyuan. Flexible Decision-Aided Maximum Likelihood Phase Estimation for Optical Coherent QAM Signals[J]. Acta Optica Sinica, 2016, 36(8): 806007

    Xu Dan, Lu Bin, Yang Fei, Chen Dijun, Cai Haiwen, Qu Ronghui. Narrow Linewidth Single-Frequency Laser Noise Measurement Based on a 3×3 Fiber Coupler[J]. Chinese Journal of Lasers, 2016, 43(1): 102004
    Download Citation