• Acta Photonica Sinica
  • Vol. 47, Issue 4, 414002 (2018)
SHI Hao1、2、*, MA Jie1, LI Xiao-feng1, LIU Jie1, and ZHANG Shou-gang1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/gzxb20184704.0414002 Cite this Article
    SHI Hao, MA Jie, LI Xiao-feng, LIU Jie, ZHANG Shou-gang. Compact Frequency Stabilized Laser for Optically Pumped Cs Beam Clocks[J]. Acta Photonica Sinica, 2018, 47(4): 414002 Copy Citation Text show less
    References

    [1] CHEN Jing-biao, ZHU Cheng-jin, WANG Feng-zhi, et al. A new pumping-probing scheme for the optically pumped cesium beam frequency standard[J]. Chinese Physics Letters, 2001, 18(1): 16-17.

    [2] GHEZALI S, LAURENT PH, LEA S N, et al. An experimental study of the spin-exchange frequency shift in a laser-cooled cesium fountain frequency standard[J]. Europhysics Letters, 2007, 36(1): 25-30.

    [3] MORETTI D, FELINTO D, TABOSA J W R. Collapses and revivals of stored orbital angular momentum of light in a cold-atom ensemble[J]. Physical Review A, 2009, 79(2): 718-722.

    [4] DURFEE D S, SHAHAM Y K, KASEVICH M A. Long-term stability of an area-reversible atom-interferometer sagnac gyroscope[J]. Physical Review Letters, 2006, 97(24): 240801-240804.

    [5] LEE H S, BAEK K J, KWON T Y, et al. Velocity distribution and second-order Doppler shift in an optically pumped cesium beam frequency standard[J]. IEEE Transactions on Instrumentation & Measurement, 2002, 48(2): 492-495.

    [6] SANG E P, LEE H S, SHIN E, et al. Generation of a slow and continuous cesium atomic beam for an atomic clock[J]. Journal of the Optical Society of America B, 2002, 19(11): 2595-2602.

    [7] LI Xiao-feng. Research on the key technology of small optically pumped cesium beam frequency standard[D]. Beijing: University of Chinese Academy of Sciences, 2015.

    [8] SHI Hao, MA Jie, LI Xiao-feng, et al. Simulation and design of fluorescence collector[J]. Chinese Physics Letters, 2016, 33(9): 094205.

    [9] WANG Qing, DUAN Jun, QI Xiang-Hui, et al. Improvement of laser frequency stabilization for the optical pumping cesium beam standard[J]. Chinese Physics Letters, 2015, 32(5): 054206.

    [10] HAAMSH. Corrections for second-order doppler shift and cavity phase error in cesium atomic beam frequency standards[J]. IEEE Transactions on Instrumentation & Measurement, 2007, 23(4): 509-514.

    [11] HISADOME H, KINARA M.Design of stabilized laser for optically pumped atomic frequency standards[J]. Electrical Engineering in Japan, 2001, 136(2): 31-37.

    [12] LECOMTE S, HALDIMANN M, RUFFIEUX R, et al. Performance demonstration of a compact, single optical frequency Cesium beam clock for space applications[C]. In proceedings of Frequency Control Symposium, 2007 Joint with the 21st European Frequency and Time Forum. IEEE International, 2007, 1127-1131.

    [13] HERMANN V, GAZARD M, BERTHOUD P, et al. OSCC project: A space Cs beam optically pumped atomic clock for Galileo[C]. In proceedings of Frequency Control Symposium, 2007 Joint with the 21st European Frequency and Time Forum, 2007, 77-80.

    [14] SALLOT C, BALDY M, GIN D, et al. 3·10-12 τ-1/2 on industrial prototype optically pumped cesium beam frequency standard[C]. In the proceeding of Frequency Control Symposium and PDA Exhibition Jointly with the 17th European Frequency and Time Forum, 2003, 100-104.

    [15] ZHANG Xian, HUANG Kai-kai, XU Hao, et al. A compact setup of SAS for diode laser frequency stabilization[J]. Chinese Physics Letters, 2012, 29 (7): 74206-74209.

    [16] IM K B, JUNG H Y, OH C H, et al. Saturated absorption signals for the Cs D2 line[J]. Physics Review A, 2001, 63(3): 222-224.

    [17] MAGUIRE L P, MESE E, SCHOLTEN R E, et al. Theoretical calculation of saturated absorption spectra for multi-level atoms[J]. Journal of Physics B Atomic Molecular & Optical Physics, 2006, 39(12): 2709-2720.

    [18] WANG Xi, WANG Yong, DUAN Li-na,et al. LD side-pumped passive mode-locked: YAG laser with semiconductor saturable absorption mirror[J]. Acta Photonica Sinica, 2015, 44(7): 0714001.

    [19] HASEGAWA A, FUKUDA K, KAJITA M, et al. Accuracy evaluation of optically pumped primary frequency standard CRL-O1[J]. Metrologia, 2004, 41(4): 257-263.

    [20] WANG Meng-yu, JIN Xue-ying, WANG Jing, et al. Analysis of the pound-drever-hall frequency stabilization technique based on a whispering gallery mode optical microsphere cavity[J]. Acta Photonica Sinica, 2017, 46(7): 0706003.

    SHI Hao, MA Jie, LI Xiao-feng, LIU Jie, ZHANG Shou-gang. Compact Frequency Stabilized Laser for Optically Pumped Cs Beam Clocks[J]. Acta Photonica Sinica, 2018, 47(4): 414002
    Download Citation