• Acta Photonica Sinica
  • Vol. 47, Issue 1, 129002 (2018)
GAO Jing1、*, HAN Guang2、3, and LU Qi-peng4
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • 4[in Chinese]
  • show less
    DOI: 10.3788/gzxb20184701.0129002 Cite this Article
    GAO Jing, HAN Guang, LU Qi-peng. Propagation of Near-infrared Light in Skin Tissue and the Design of Optical Fiber Detection Structure[J]. Acta Photonica Sinica, 2018, 47(1): 129002 Copy Citation Text show less
    References

    [1] DING Hai-quan, LU Qi-peng, PENG Zhong-qi, et al. Progress in noninvasive biochemical examination by near infrared spectroscopy[J]. Spectroscopy and Spectral Analysis, 2010, 30(8): 2107-2110.

    [2] YANG Hai-qing, KUANG Bo-yan, MOUAZEN A M. In situ determination of growing stages and harvest time of tomato (lycopersicon esculentum) fruits using fiber-optic visible-near-infrared (Vis-NIR) spectroscopy[J]. Applied Spectroscopy, 2011, 65(8): 931-938.

    [3] HAN Jun, SUN Chang-hai, CHEN Ai-ming, et al. Near infrared diffuse reflectance spectroscopy for rapid detection of the excipients′ contents in amlodipine besylate tablets[J]. Acta Photonica Sinica, 2017, 46(1): 0112006.

    [4] ZHAN Hao, FANG Jing, YANG Bin, et al. Determination of osthole and columbianadin in angelicae pubescentis radix with near infrared spectroscopy[J]. Spectroscopy and Spectral Analysis, 2017, 37(4): 1110-1113.

    [5] NORRIS K. Possible medical applications of NIR[M]. Making light work: Advances in near infrared spectroscopy. Aberdeen: Ian Michael Publication, 1992, 596-602.

    [6] KRAMER K E, SMALL G W. Robust absorbance computations in the analysis of glucose by near-infrared spectroscopy[J]. Vibrational Spectroscopy, 2007, 43: 440-446.

    [7] HUANG Zhen-hao, HAO Chang-ning, ZHANG Lin-lin, et al. Non-invasive blood glucose sensing on human body with near-infrared reflection spectroscopy[C]. SPIE, 2011, 8193(4): 393-403.

    [8] MIN Xiao-lin, LIU Rong, FU Bo, et al. A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing[J]. Optics & Laser Technology, 2017, 91: 7-12.

    [9] CHEN Xing-dan, GAO Jing, DING Hai-quan. Infrared spectroscopy for non-invasive blood glucose monitoring (Invited)[J]. Chinese Optics, 2012, 5(4): 317-326.

    [10] YADAV J, RANI A, SINGH V, et al. Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy[J]. Biomedical Signal Processing and Control, 2015, 18: 214-227.

    [11] Wang L H, JAEQUES S L, ZHENG Li-qiong. MCML-Monte Carlo modeling of light transport in multi-layered tissues[J]. Computer Methods and Programs in Biomedicine, 1995, 47: 131-146.

    [12] WANG Ji-hui, DING Yan, CHEN Song-lin, et al. Transport for photon beams of finite size in biological tissues based on Monte Carlo[J]. Acta Photonica Sinica, 2014, 43: 0117001.

    [13] XU Li-li. Transmission for planar light source in biological tissue based on Monte Carlo simulation[J]. Laser & Infrared, 2016, 46(6): 665-668.

    [14] SAKOTA D, TAKATANI S. Quantitative analysis of optical properties of flowing blood using a photon-cell interactive Monte Carlo code: effects of red blood cells′ orientation on light scattering[J]. Journal of Biomedical Optics, 2012, 17(5): 057007.

    [15] MAEDA T, ARAKAWA N, TAKAHASHI M, et al. Monte Carlo simulation of spectral reflectance using a multilayered skin tissue model[J]. Optical Review, 2010, 17(3): 223-229.

    [16] WANG Xi-chang. Steady-state diffusion equation of light in semi-infinite multilayer rectangular biological tissues[J]. Acta Optica Sinica, 2016, 36(3): 0317003.

    [17] MARUO K, TSURUGI M, TAMURA M, et al. In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy[J]. Applied Spectroscopy, 2003, 57(10): 1236-1244.

    [18] TROY T L, THENNADIL S N. Optical properties of human skin in the near infrared wavelength range of 1 000 to 2 200 nm[J]. Journal of Biomedical Optics, 2001, 6(2): 167-176.

    [19] SEGELSTEIN D J. The complex refractive index of water[D]: [Master Dissertation]. Kansas City: University of Missouri-Kansas City, 1981, 116-144.

    [20] IINO K, MARUO K. Monte Carlo simulation of near infrared reflectance spectroscopy in the wavelength range from 1 000 nm to 1 900 nm[J]. Optical Review, 2003, 10(6): 600-606.

    CLP Journals

    [1] WANG Xing, LI Wen-yan, QIAO Yan-qing, LIU Ying. Method to Quantitate Parameter γ Related to Tissue Microstructure by Reflectance Measured at Microdomains Close to the Source[J]. Acta Photonica Sinica, 2018, 47(9): 917002

    GAO Jing, HAN Guang, LU Qi-peng. Propagation of Near-infrared Light in Skin Tissue and the Design of Optical Fiber Detection Structure[J]. Acta Photonica Sinica, 2018, 47(1): 129002
    Download Citation