• Acta Photonica Sinica
  • Vol. 41, Issue 2, 148 (2012)
ZOU Ren-ling1、2、*, CHEN Bao-xue3、4, WANG You-you3, SUI Guo-rong3, and MAMORU Iso5
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • 4[in Chinese]
  • 5[in Chinese]
  • show less
    DOI: 10.3788/gzxb20124102.0148 Cite this Article
    ZOU Ren-ling, CHEN Bao-xue, WANG You-you, SUI Guo-rong, MAMORU Iso. Biochemical Solution Concentration Sensing Using Stripe Waveguides Based on Ion Exchange Technology[J]. Acta Photonica Sinica, 2012, 41(2): 148 Copy Citation Text show less
    References

    [1] WANG Zhen-yuan, GU Zheng-tian. Optical humidity sensor[J]. Laser & Optoelectronics Progress, 2007, 44(11):41-46.

    [2] HAES A J,DUYNE R P V.Preliminary studies and potential applications of localized surface plasmon resonance spectroscopy in medical diagnostic[J].Expert Review of Molecular Diagnostics,2004,4(1):527-537.

    [3] CHUNG J W,KIM S D,BERNHARDT R, et al. Application of SPR biosensor for medical diagnostics of human hepatitis B virus 0aI-mv[J].Sensor Actuators B,2005,11(2):416-422.

    [4] XIE Xiao,LIU Quan-jun,LU Zu-hong.The development of biomedical detection by optical waveguide light mode spectroscopy system[J]. Laser & Optoelectronics Progress, 2006,43(11):33-42.

    [5] ZOU Ren-ling,CHEN Bao-xue,WANG Hai-hong.The sensing structure optimization of planer optical waveguide with fermi refractive index [J].Journal of Lightwave Technology,2010,28(23):3439-3443.

    [6] JOHANSSON J,DJANTA G,COUTAS J L.Optical waveguides fabricated by ion exchange in high-index commercial glasses[J].Applied Optics,1992,31(15):2796-2799.

    [7] ALBERT J,YIP G L.Wide single-mode channels and directional coupler by two-step ion-exchange in glass[J].Journal of Lightwave Technology,1988,6(4):552-563.

    [8] SUI Guo-rong,CHEN Bao-xue,ZHANG Xiao-wei,et al.Automatic waveguide-fiber coupling system based on multi-objective evolutionary algorithm[J].Applied Optics,2007,46(30):7452-7459.

    [9] PEIPONEN K E,VATIAINEN E M.Kramers-Kronig relations in optical data inversion[J].Physical Review B,1991,44(2): 8301-8303.

    [10] JIANG Li-ying,CAI Xin-xia,LIU Hong-min,et al.Research on biosensor for low concentration glucose determination[J].Instrument Technique and Sensor,2009,2(2):1-4.

    ZOU Ren-ling, CHEN Bao-xue, WANG You-you, SUI Guo-rong, MAMORU Iso. Biochemical Solution Concentration Sensing Using Stripe Waveguides Based on Ion Exchange Technology[J]. Acta Photonica Sinica, 2012, 41(2): 148
    Download Citation