• Acta Photonica Sinica
  • Vol. 48, Issue 6, 611004 (2019)
YAN Yu1、*, XU Xiao-hong1, FAN Zhi-guo1, ZHANG Qiang1, and JIN Hai-hong1、2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/gzxb20194806.0611004 Cite this Article
    YAN Yu, XU Xiao-hong, FAN Zhi-guo, ZHANG Qiang, JIN Hai-hong. Calibration Method of Micro-polarizer Array Long-wave Infrared Imaging System[J]. Acta Photonica Sinica, 2019, 48(6): 611004 Copy Citation Text show less

    Abstract

    To improve the precision of micro-polarizer array long-wave infrared imaging system, for the incident light’s polarimetric information calculation problem, a polarimetric calibration method is proposed based on error analysis. By determining the relationship between the pixel level response values and the incident light power, the generalized optical transmittance is introduced to derive and achieve the calculation of the extinction ratio and polarization orientation, further obtain the values of elements in the micro-polarizer Mueller matrix independent of large scale equations. A method to compute polarimetric information in one super pixel which contains fixed position blind pixels is proposed, contribute to getting the incident light’s polarimetric information precisely. The experiments show that this calibration method can effectively reduce error interference, and improve the detection accuray of micro-polarizer array long-wave infrared imaging system.
    YAN Yu, XU Xiao-hong, FAN Zhi-guo, ZHANG Qiang, JIN Hai-hong. Calibration Method of Micro-polarizer Array Long-wave Infrared Imaging System[J]. Acta Photonica Sinica, 2019, 48(6): 611004
    Download Citation