• Acta Physica Sinica
  • Vol. 68, Issue 19, 198301-1 (2019)
Qing-Ming Huang1、2、3、4, Shan-Shan Chen2、3, Jian-Qing Zhang2、3, Yang Yang2, and Gang Zheng1、4、*
Author Affiliations
  • 1School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
  • 2School of Medical Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
  • 3Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
  • 4Laboratory of Medical Imaging Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
  • show less
    DOI: 10.7498/aps.68.20190612 Cite this Article
    Qing-Ming Huang, Shan-Shan Chen, Jian-Qing Zhang, Yang Yang, Gang Zheng. Method of designing magnetic resonance active shimming coil based on target field point method and flow function[J]. Acta Physica Sinica, 2019, 68(19): 198301-1 Copy Citation Text show less

    Abstract

    Uniformity of magnetic field is an important parameter of magnetic resonance system. Improving the uniformity of magnetic field is helpful for detecting the magnetic resonance time domain signal and improving the resolution of magnetic resonance frequency domain signal. Based on the idea of continuous current density distribution in an active shimming field, the shimming coil is designed by combining the target field point method with the current function method. That is to say, the relationship between magnetic field distribution and current density is determined by Biot-Savart law. After confining the coil radius and setting the constraint point, the current density distribution on the coil plane is inversely solved according to the target field distribution. Then the current density distribution is discretized by the current function, and the winding position distribution of the uniform field coil is obtained. According to the results of electromagnetic simulation, the first-order and second-order shimming coils are fabricated and applied to the magnetic resonance analyzer. The experimental results show that the shimming coils can effectively improve the magnetic field uniformity of the permanent magnet in nuclear magnetic resonance (NMR) system.
    Qing-Ming Huang, Shan-Shan Chen, Jian-Qing Zhang, Yang Yang, Gang Zheng. Method of designing magnetic resonance active shimming coil based on target field point method and flow function[J]. Acta Physica Sinica, 2019, 68(19): 198301-1
    Download Citation