• Chinese Journal of Lasers
  • Vol. 48, Issue 16, 1604003 (2021)
Yan Liang1、2, Youjian Yi2、3, Ping Zhu2、*, Dongjun Zhang2、3, Zhan Li2、3, Xinglong Xie2、3、**, Jun Kang2, Qingwei Yang2, Meizhi Sun2, Xiao Liang2, Haidong Zhu2, Ailin Guo2, Qi Gao2, Xiaoping Ouyang2, Donghui Zhang2、3, Linjun Li2、3, and Jianqiang Zhu1、2、3、***
Author Affiliations
  • 1School of Physical Science and Technology, ShanghaiTech University, Shanghai 200120, China
  • 2Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
  • 3Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/CJL202148.1604003 Cite this Article Set citation alerts
    Yan Liang, Youjian Yi, Ping Zhu, Dongjun Zhang, Zhan Li, Xinglong Xie, Jun Kang, Qingwei Yang, Meizhi Sun, Xiao Liang, Haidong Zhu, Ailin Guo, Qi Gao, Xiaoping Ouyang, Donghui Zhang, Linjun Li, Jianqiang Zhu. Single-Shot Synchronous Measurement Technique for Multichannel Ultra-Short Pulse Lasers Based on All-Fiber Spectral Interference[J]. Chinese Journal of Lasers, 2021, 48(16): 1604003 Copy Citation Text show less
    Schematic of time synchronization measurement of multiple laser pulses based on all-fiber spectral interferometry
    Fig. 1. Schematic of time synchronization measurement of multiple laser pulses based on all-fiber spectral interferometry
    2D all-fiber spectral interferometry spectrogram measured by 12 laser pulse time synchronization
    Fig. 2. 2D all-fiber spectral interferometry spectrogram measured by 12 laser pulse time synchronization
    Experimental light path
    Fig. 3. Experimental light path
    Experimental spectrogram obtained by spectrometer
    Fig. 4. Experimental spectrogram obtained by spectrometer
    Range of measurements in the experiment. (a) Spectrum interference waveform of the minimum measured value; (b) temporal waveform of the minimum measured value; (c) spectrum interference waveform of the maximum measured value; (d) temporal waveform of the maximum measured value; (e) temporal waveform at τ=5 ps; (f) temporal waveform at τ=10.2 ps
    Fig. 5. Range of measurements in the experiment. (a) Spectrum interference waveform of the minimum measured value; (b) temporal waveform of the minimum measured value; (c) spectrum interference waveform of the maximum measured value; (d) temporal waveform of the maximum measured value; (e) temporal waveform at τ=5 ps; (f) temporal waveform at τ=10.2 ps
    Relationship between measurement error and pulse spacing
    Fig. 6. Relationship between measurement error and pulse spacing
    Yan Liang, Youjian Yi, Ping Zhu, Dongjun Zhang, Zhan Li, Xinglong Xie, Jun Kang, Qingwei Yang, Meizhi Sun, Xiao Liang, Haidong Zhu, Ailin Guo, Qi Gao, Xiaoping Ouyang, Donghui Zhang, Linjun Li, Jianqiang Zhu. Single-Shot Synchronous Measurement Technique for Multichannel Ultra-Short Pulse Lasers Based on All-Fiber Spectral Interference[J]. Chinese Journal of Lasers, 2021, 48(16): 1604003
    Download Citation