• Optics and Precision Engineering
  • Vol. 22, Issue 12, 3191 (2014)
YAN Ya-dong1,*, HE Jun-hua1, WANG Feng2, and ZHANG Min1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/ope.20142212.3191 Cite this Article
    YAN Ya-dong, HE Jun-hua, WANG Feng, ZHANG Min. Optical system for full aperture backscatter diagnosis[J]. Optics and Precision Engineering, 2014, 22(12): 3191 Copy Citation Text show less
    References

    [1] XU Y, LAI D X, FENG T G, et al.. A model to study the transmissivity of diagnostic holes on hohlraum[J]. High Power Laser and Particle Beams, 2001,13(2): 173-176. (in Chinese)

    [2] ZHENG ZH J, CHEN J B, DING Y K, et al.. The laser energy injection efficiency measurement for the half-cavity target[J]. High Power Laser and Particle Beams, 2000,12(1): 43-47. (in Chinese)

    [3] KUANG L Y, WANG CH K, WANG ZH B, et al.. Angular distribution of stimulated Brillouin scattering from interaction of 527 nm laser with Au and Al disk targets[J]. High Power Laser and Particle Beams, 2007,19(3): 413-416. (in Chinese)

    [4] KIRKWOOD R K,MCCARVILLE T,FROULA D H, et al.. Calibration of initial measurements from the full aperture backscatter system on the National Ignition Facility[J]. Rev. Sci. Instrum., 2004, 75(10): 4174-4176.

    [5] BOWER D E, MCCARVILLE T J,ALVAREZ S S, et al.. Full aperture backscatter station measurement system on the National Ignition Facility[J]. Rev. Sci. Instrum., 2004, 75(10): 4177-4179.

    [6] MOODY J D,DATTE P,KRAUTER K, et al.. Backscatter measurements for NIF ignition targets[J]. Rev. Sci. Instrum., 2010, 81(10): 921.1-921.6.

    [7] WANG CH K, JIANG X H, LIU SH Y, et al.. Stimulated Raman scattering from interaction of 2 ns, 351 nm laser with hohlraum[J]. High Power Laser and Particle Beams, 2006,18(7): 1113-1116. (in Chinese)

    [8] WANG CH K, ZHANG X D, YANG D, et al.. Energy fraction measurements of stimulated Brillouin scattering and stimulated Raman scattering on Shenguang Ⅲ prototype laser facility[J]. High Power Laser and Particle Beams, 2010,22(8): 1891-1895. (in Chinese)

    [9] ZHAO X F, WANG CH K, KUANG L Y,et al.. The experimental method of measurement for spatial distribution of full aperture backscatter light by circular PIN-array[J].Nuclear Fusion and Plasma Physics, 2011,31(1): 43-47. (in Chinese)

    [10] JIAO CH Y, WANG F, JIANG X H, et al.. Full aperture backscatter diagnosis system on Shenguang prototype laser facility[J]. Nuclear Electronics & Detection Technology, 2011,31(3): 306-311. (in Chinese)

    [11] YANG ZH H. The study of near backscatter and full-aperture backscatter measurement system[D]. Chongqing: Chongqing university, 2008. (in Chinese)

    [12] WANG CH K, JIANG X H, WANG ZH B, et al.. Full-aperture backscatter station on Shenguang-Ⅱ laser facility[J]. High Power Laser and Particle Beams, 2010,22(8): 1896-1900. (in Chinese)

    [13] WEI H Y, PENG X SH, XU T, et al.. Full aperture backscatter diagnostic system on Shenguang-Ⅲprototype laser facility[J]. High Power Laser and Particle Beams, 2012,24(12): 2273-2277. (in Chinese)

    [14] WANG M C, CHEN G, HUANG ZH, et al.. Stability design of switchyard in SG-Ⅲ facility[J]. Opt. Precision Eng., 2011,19(11): 2664-2670.(in Chinese)

    [15] SONG J B, LI G P. Design and simulation of splicing of sector-shaped segments of a large optical telescope[J]. Astronomical Research & Technology, 2010,7(4): 355-361. (in Chinese)

    [16] ZHANG R, HAN J J, ZANG Y ZH, et al.. Technology of segmented collimating mirror in a large solar simulator[J]. Spacecraft Environment Engineering, 2005,22(1): 50-56. (in Chinese)

    [17] YANG B X. Research of SiC reflection mirror for space camera[J]. Spacecraft Recovery & Remote Sensing. 2003,24(1): 15-18.(in Chinese)

    [18] WANG G L, LI SH Y, DAI Y F. Fabrication of SiC mirrors applied to space camera[J]. Materials for Mechanical Engineering, 2002,26(8): 37-38.(in Chinese)

    [19] ZHANG X J, LI ZH L, ZHANG ZH Y. Space telecope aspherical mirror structure design based on SiC material[J]. Infrared and Laser Engineering, 2007,36(5): 577-582. (in Chinese)

    [20] CHEN W, DING Y L, HUI SH W, et al.. Design of kinematic mount for SiC scanning reflective mirror[J]. Chinese Optics, 2012,5(2): 161-166.(in Chinese)

    [21] XU X H, WANG B, QIAO J, et al.. Lightweight design of mirror in fast-steering mirror system[J]. Chinese Optics, 2012,5(1): 35-41.(in Chinese)

    CLP Journals

    [1] Hou Pengcheng, Zhong Zheqiang, Wen Ping, Zhang Bin. Irradiation characteristics of laser quads on cylindrical hohlraum wall in indirect-drive facility[J]. Infrared and Laser Engineering, 2016, 45(11): 1106001

    [2] Zhou Chenghu1, Zhang Qiuhui, Huang Mingming, Huang Quanzhen. Damage effects of impurity particles on film[J]. Infrared and Laser Engineering, 2016, 45(7): 721004

    YAN Ya-dong, HE Jun-hua, WANG Feng, ZHANG Min. Optical system for full aperture backscatter diagnosis[J]. Optics and Precision Engineering, 2014, 22(12): 3191
    Download Citation