• Infrared and Laser Engineering
  • Vol. 44, Issue 7, 2169 (2015)
Gao Siyuan1、2、*, Liu Hui1, Zhu Mingchao1, Zhang Xin1, and Bai Yang1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: Cite this Article
    Gao Siyuan, Liu Hui, Zhu Mingchao, Zhang Xin, Bai Yang. Analysis and optimization of angle measurement accuracy of strap-down laser semi-active guidance seeker[J]. Infrared and Laser Engineering, 2015, 44(7): 2169 Copy Citation Text show less

    Abstract

    In order to reduce the cost of the laser guidance weapons system and improve its accuracy, the strap-down laser guided seeker was designed. The precision of angle measurement which affecting the attack precision was studied. First, the method of gain controlling affecting the precision of angle measurement was analyzed. Second, the four channel variable gain amplifier was calibrated and the least squares fitting curve of the gain was got. Then, the method of gain compensation and its error under the discrete control were discussed. Finally, the error of light spot between uncompensated and compensated in different amplified mode by simulation was got. Experimental results indicate that the system error is decreased by 5.6 mrad. The precision of angle measurement reach to 2 mrad in the linear field of view. It can satisfy the system requirements by semi-active laser guidance weapons system.
    Gao Siyuan, Liu Hui, Zhu Mingchao, Zhang Xin, Bai Yang. Analysis and optimization of angle measurement accuracy of strap-down laser semi-active guidance seeker[J]. Infrared and Laser Engineering, 2015, 44(7): 2169
    Download Citation