• Chinese Journal of Lasers
  • Vol. 48, Issue 20, 2004001 (2021)
Suochao Yuan1、2, Ming Li1、2、**, and Zhengshang Da1、*
Author Affiliations
  • 1Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an, Shanxi 710119, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.3788/CJL202148.2004001 Cite this Article Set citation alerts
    Suochao Yuan, Ming Li, Zhengshang Da. Calibration Method for Structural Parameters and Assembly Error of Light Field Camera[J]. Chinese Journal of Lasers, 2021, 48(20): 2004001 Copy Citation Text show less
    Structure of light field camera
    Fig. 1. Structure of light field camera
    Rotation error between microlens array and sensor
    Fig. 2. Rotation error between microlens array and sensor
    Tilt error between microlens array and sensor
    Fig. 3. Tilt error between microlens array and sensor
    Calibration principle of structure parameters
    Fig. 4. Calibration principle of structure parameters
    Calibration principle of tilt error
    Fig. 5. Calibration principle of tilt error
    Calibration device and results of structural parameters. (a) Experimental device; (b) calibration image without spacer; (c) calibration image with spacer
    Fig. 6. Calibration device and results of structural parameters. (a) Experimental device; (b) calibration image without spacer; (c) calibration image with spacer
    Calibration of rotation error. (a) Calibration image; (b) linear fitting result of spot centroid
    Fig. 7. Calibration of rotation error. (a) Calibration image; (b) linear fitting result of spot centroid
    Calibration of tilt error. (a) Calibration image of normal incidence; (b) calibration image with incident angle of 6°
    Fig. 8. Calibration of tilt error. (a) Calibration image of normal incidence; (b) calibration image with incident angle of 6°
    Process of light field reconstruction
    Fig. 9. Process of light field reconstruction
    Light field acquisition and reconstruction. (a) Light field acquisition; (b)raw light field image; (c)reconstructed image of close view before calibration; (d)reconstructed image of distant view before calibration; (e)reconstructed image of close view after calibration; (f)reconstructed image of distant view after calibration
    Fig. 10. Light field acquisition and reconstruction. (a) Light field acquisition; (b)raw light field image; (c)reconstructed image of close view before calibration; (d)reconstructed image of distant view before calibration; (e)reconstructed image of close view after calibration; (f)reconstructed image of distant view after calibration
    ParameterNominal valueCalibration value
    Distance between microlens array and sensor plane2.13002.2738
    Distance between centers of adjacent microlens0.30000.3001
    Distance between microlens array and exit pupil of main lens47.7058
    Table 1. Calibration results of structural parameters unit: mm
    Suochao Yuan, Ming Li, Zhengshang Da. Calibration Method for Structural Parameters and Assembly Error of Light Field Camera[J]. Chinese Journal of Lasers, 2021, 48(20): 2004001
    Download Citation