• NUCLEAR TECHNIQUES
  • Vol. 47, Issue 7, 070302 (2024)
Xiaojun LU, Jiayu LIU, Chongqing HU, Gang HAN..., Jiaban SONG, Linfeng HE and Jinxue CHANG*|Show fewer author(s)
Author Affiliations
  • Shanghai Institute of Measurement and Testing Technology, Shanghai 201203, China
  • show less
    DOI: 10.11889/j.0253-3219.2024.hjs.47.070302 Cite this Article
    Xiaojun LU, Jiayu LIU, Chongqing HU, Gang HAN, Jiaban SONG, Linfeng HE, Jinxue CHANG. Optimization study on the size of medical radioactive waste liquid sampling container[J]. NUCLEAR TECHNIQUES, 2024, 47(7): 070302 Copy Citation Text show less
    References

    [2] ZHANG Sheng, WANG Yongjun, WANG Ruijun et al. Development of an online monitoring system for water body γ radioactivity based on 4G-RTU[J]. Nuclear Techniques, 47, 010402(2024).

    [3] GUO Shengliang, XIANG Yezhou, GE Liangquan et al. Design of calibration device for real-time on-line monitoring system of water radioactivity[J]. Nuclear Techniques, 46, 010401(2023).

    [4] Klemola S. Optimization of sample geometries in low-level gamma spectroscopy[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 369, 578-581(1996).

    [5] Park T S, Jeon W J. Measurement of radioactive samples in Marinelli beakers by gamma-ray spectrometry[J]. Journal of Radioanalytical and Nuclear Chemistry, 193, 133-144(1995).

    [6] Ahmed A S, Capello K, Chiang A et al. Optimization of geometric parameters for Marinelli beaker to maximize the detection efficiency of an HPGe detector[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 610, 718-723(2009).

    [7] Zamzamian S M, Hosseini S A, Samadfam M. Optimization of the marinelli beaker dimensions using genetic algorithm[J]. Journal of Environmental Radioactivity, 172, 81-88(2017).

    [8] Zamzamian S M, Hosseini S A, Feghhi S A et al. Determining of the optimized dimensions of the Marinelli beaker containing source with inhomogeneous emission rate by using genetic algorithm coupled with MCNP and determining distribution type by neural networks[J]. Applied Radiation and Isotopes: Including Data, Instrumentation and Methods for Use in Agriculture, Industry and Medicine, 157, 109039(2020).

    [9] XU Feng, YU Guobing, XU Ping et al. Geometric correction of marinelli BeakerSource in gamma spectrometry[J]. Nuclear Electronics & Detection Technology, 41, 1074-1079(2021).

    [10] MA Yunxing, BAI Lixin. Application of MCNP code in selection of optimum shape for saddle-like sample box of HPGe detector[J]. Atomic Energy Science and Technology, 43, 1039-1042(2009).

    [11] WANG Shuo, YANG Baolu, ZHOU Qiang et al. Application of sourceless efficiency calibration in activity measurement of gas source in Marinelli beaker[J]. Chinese Journal of Radiological Health, 31, 6-12(2022).

    [12] ZHU Yue. Study on photosensitive resin for 3D printing[J]. Shanxi Chemical Industry, 40, 34-37(2020).

    [13] DU Yue, LIN Min, XU Lijun et al. Feasibility study on preparation of photosensitive resin for 137Cs 3D printing by phase transfer method[J]. Journal of Isotopes, 36, 20-28(2023).

    [14] Currie L A. Limits for qualitative detection and quantitative determination. Application to radiochemistry[J]. Analytical Chemistry, 40, 586-593(1968).

    Xiaojun LU, Jiayu LIU, Chongqing HU, Gang HAN, Jiaban SONG, Linfeng HE, Jinxue CHANG. Optimization study on the size of medical radioactive waste liquid sampling container[J]. NUCLEAR TECHNIQUES, 2024, 47(7): 070302
    Download Citation