• Chinese Journal of Lasers
  • Vol. 49, Issue 2, 0202014 (2022)
Yaorui Ma, Chuang Cai*, Zhijie Liu, Jia Xie, and Ce Yang
Author Affiliations
  • Institute of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, Sichuan 610031, China
  • show less
    DOI: 10.3788/CJL202249.0202014 Cite this Article Set citation alerts
    Yaorui Ma, Chuang Cai, Zhijie Liu, Jia Xie, Ce Yang. Plasma Monitoring During Laser-MIG Hybrid Welding Process Based on LabVIEW[J]. Chinese Journal of Lasers, 2022, 49(2): 0202014 Copy Citation Text show less

    Abstract

    Conclusions

    In this study, a laser-MIG hybrid welding monitoring system was designed based on the LabVIEW environment and the accuracy of the monitoring system was verified via experiments. The conclusions are as follows:

    1) The designed monitoring system was capable of monitoring plasma signals and had three functions: saving plasma signals in TDMS format, saving process parameters, and playback of data.

    2) Binarization processing, morphological filters, HUBER linear fitting, and path-tracing-based bifurcation removal algorithms were used to locate the wire and workpiece successfully. Thus, we calculated the distance of laser transmission through the hybrid plasma.

    3) The monitoring system extracted DLTP values from the plasma images and output them. Compared with the DLTP value obtained via the image analysis software, the accuracy of the DLTP value calculated by the system reached about 96.5%.

    Yaorui Ma, Chuang Cai, Zhijie Liu, Jia Xie, Ce Yang. Plasma Monitoring During Laser-MIG Hybrid Welding Process Based on LabVIEW[J]. Chinese Journal of Lasers, 2022, 49(2): 0202014
    Download Citation