• NUCLEAR TECHNIQUES
  • Vol. 47, Issue 11, 110202 (2024)
Yiming XU, Chengcheng XIAO*, and Wencheng FANG*
Author Affiliations
  • Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201204, China
  • show less
    DOI: 10.11889/j.0253-3219.2024.hjs.47.110202 Cite this Article
    Yiming XU, Chengcheng XIAO, Wencheng FANG. Design and test of multi-variable estimation-based calibration for vector modulator[J]. NUCLEAR TECHNIQUES, 2024, 47(11): 110202 Copy Citation Text show less
    References

    [1] Feng C, Deng H X. Review of fully coherent free-electron lasers[J]. Nuclear Science and Techniques, 29, 160(2018).

    [2] ZHAO Zhentang, WANG Dong, YIN Lixin et al. Shanghai soft X-ray free-electron laser facility[J]. Chinese Journal of Lasers, 46, 33-42(2019).

    [3] FANG Wencheng, TAN Jianhao, ZHANG Junqiang et al. Microwave system of soft X-ray free electron laser test facility[J]. Vacuum Electronics, 32-37, 46(2021).

    [4] Liu B, Feng C, Gu D et al. The SXFEL upgrade: from test facility to user facility[J]. Applied Sciences, 12, 176(2021).

    [5] GONG Pengpeng, ZHAO Yubin, HOU Hongtao et al. Front-end frequency conversion module design for harmonic RF system in SSRF[J]. Nuclear Techniques, 42, 010101(2019).

    [6] Xu Y M, Zhang J Q, Xiao C C et al. Design and verification of adaptive control to generate flat-top radio frequency power output of pulse compressor for SXFEL[J]. Nuclear Instruments and Methods in Physics Research A, 1031, 166596(2022).

    [7] DU Chaohai, LIU Pukun, XUE Qianzhong et al. An ultra-high gain gyrotron traveling-wave amplifier with high stability[J]. Journal of Electronics & Information Technology, 32, 1717-1720(2010).

    [8] QUAN Xin, ZHANG Mengyao, LIU Jian et al. Linearization of analog domain power amplifier based on two-channel nonlinear feedback architecture[J]. Journal of Electronics & Information Technology, 45, 4211-4217(2023).

    [9] CHEN Lei, YUE Guangrong, TANG Junlin et al. Calibration of transmitter I/Q imbalance based on digital pre-distortion[J]. Journal of Electronics & Information Technology, 39, 847-853(2017).

    [10] WU Huanming, YANG Haigang, YIN Tao et al. A low noise micro-gyroscope interface circuit on chip with demodulation signal phase calibration technique[J]. Journal of Electronics & Information Technology, 35, 2524-2531(2013).

    [11] LI Song, ZHANG Junqiang, ZHANG Meng et al. Implementation of FPGA-based feedforward function in LLRF system for electron LINAC[J]. Nuclear Techniques, 39, 070402(2016).

    [12] Wang C, Miao J G. Implementation and broadband calibration of a multichannel vector modulator module[J]. IET Science, Measurement & Technology, 11, 155-163(2017).

    [13] XU Yiming. Technology research of low level radio frequency control system based on adaptive algorithm[D](2022).

    [14] XIAO Chengcheng, YIN Zhe, ZHANG Junqiang et al. Design and test of a C band local oscillator and clock device in LLRF[J]. Nuclear Techniques, 44, 010201(2021).

    [15] XU Yiming, ZHANG Junqiang, XIAO Chengcheng et al. Design and test of double PI-control loop to generate flat-top output of RF pulse compressor[J]. Nuclear Techniques, 45, 060102(2022).

    Yiming XU, Chengcheng XIAO, Wencheng FANG. Design and test of multi-variable estimation-based calibration for vector modulator[J]. NUCLEAR TECHNIQUES, 2024, 47(11): 110202
    Download Citation