• Optics and Precision Engineering
  • Vol. 18, Issue 8, 1801 (2010)
CUI Tian-gang1,2,*, WANG Yong-gang1,2, MA Dong-mei1, MA Wen-sheng1, and CHEN Bo1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: Cite this Article
    CUI Tian-gang, WANG Yong-gang, MA Dong-mei, MA Wen-sheng, CHEN Bo. Design of online measuring device for surface profile of Wolter Type I mirror[J]. Optics and Precision Engineering, 2010, 18(8): 1801 Copy Citation Text show less
    References

    [1] LEMEN J R, DUNCAN D, EDWARDS C S, et al.. Solar X-Ray Imager for GOES [J]. SPIE,2004,5171:65-76.

    [2] XIAO T Q, XIA S J. A new long trace profiler for aspheric optical surface metrology [J]. SPIE, 2002,4927:208-213.

    [3] QIAN SH N, TAKACS P Z. Equal optical path beamsplitter for a pencil beam interferometer and shearing interferometer [J]. Opt. Eng., 2003,42(4):929-934.

    [4] MORIYASU S, TAKACS P Z, KATO J, et al.. On-machine metrology with LTP (Long Trace Profiler) [J]. SPIE,2003,5180:385-392.

    [5] COCCO D,BIANCO A, SOSTERO G. A second optic head for the ELETTRA long trace profiler [J]. SPIE, 2005,5921: 59210L-1-59210L-10.

    [6] QIAN J, ASSOUFID L,MACRANDER A. Comparison of slope and height profiles for flat synchrotron X-ray mirrors measured with a long trace profiler and a PMI Fizeau interferometer [J]. SPIE, 2007, 6704: 67040C-1-67040C-7.

    [7] XUE CH X, HUO F R, ZHOU CH ZH, et al.. Research on the measuring method of the slope error of EUV/X-ray optical elements and measuring apparatus of long trace profiler [J]. SPIE, 2007,6723:67231W-1 -67231W-6.

    [8] LIU B, WANG Q P, FU S J. Investigation of long trace profiler for aspherical optics [J]. Laser & Optoelectronics Progress,2006,43(2):46-53. (in Chinese)

    [9] LI ZH, ZHAO Y, LI D CH, et al.. A Diffractive long trace profiler for large aspherical optics [J]. Acta Optica Sinica, 2002, 22(10): 4221-8221. (in Chinese)

    [10] QIAN SH N, TAKACS P Z. The penta-prism LTP: A long-trace-profiler with stationary optical head and moving penta prism [J]. Rev. Sci. Instrum. , 1995,66(3):2562-2569.

    [11] QIAN SH N,TAKACS P,SOSTERO G, et al.. Portable long trace profiler: Concept and solution [J]. Review of Scientific Instruments, 2001,72(8):3198-3204.

    [12] GUBAREV M, KESTER T, PETER Z.Takacs. Calibration of a vertical-scan long trace profiler at MSFC [J]. SPIE, 2001,4451:333-340.

    [13] HIGASHI Y,TAKAIE Y, ENDO K, et al.. A new designed ultra-high precision profiler-study on slope error measurement of a mandrel for wolter type-I mirror fabrication- [C]. Proc. 8th Int. Conf. X-ray Microscopy IPAP Conf. 2004,Series 7:192-194.

    [14] MA D M, HAN CH Y. System design of large flat mirror measurement based on pentagon prism scanning technique [J]. Electronic Measurement Technology, 2007,30(11):90-95. (in Chinese)

    [15] KUANG C F, FENG Q B, LIU B, et al.. Influences on the deflection angle of the pentagonal prism due to dithering and fabrication angle error [J]. Optical Technique, 2004,30(5):616-622. (in Chinese)

    [16] MA D M, LIU ZH X, MA L, et al.. Influences of alignment error in pentaprism scanning system and fabrication angle error on measuring accuracy of optical surface [J]. Opt. Precision Eng., 2008,16(12):2517-2523. (in Chinese)

    [17] MALLIK P C V, ZHAO CH Y, BURGE J H. Measurement of a 2-meter flat using a pentaprism scanning system [J]. Opt. Eng. 2007,42(6):023602-1-023602-9.

    [18] YELLOWHAIR J, BURGE J H. Analysis of a scanning pentaprism system for measurements of large flat mirrors [J]. Appleed Optics, 2007,46(35):8466-8474.

    CLP Journals

    [1] Li Shun, Gong Yan. Error Analysis and Correction during Measurement of Tube-Shaped Super-Smooth Mirrors Using Long Trace Profiler[J]. Acta Optica Sinica, 2011, 31(11): 1112001

    [2] YANG Li-ming, YE Hai-xian. High-precision metrology for optical components with large-apertures and large radii of curvature[J]. Optics and Precision Engineering, 2011, 19(6): 1207

    [3] ZHANG Bin-zhi, ZHANG Ge, DONG De-yi. 230 mm aperture RB-SiC mirror by reaction-formed joint[J]. Optics and Precision Engineering, 2012, 20(11): 2360

    [4] WANG Yong-gang, CUI Tian-gang, MA Wen-sheng, CHEN Bin, CHEN Bo. Removal function for fabrication of WolterⅠgrazing mirror by elastic ball tool[J]. Optics and Precision Engineering, 2011, 19(1): 10

    [5] WANG Yong-gang, CUI Tian-gang, MA Wen-sheng, CHEN Bin, CHEN Bo. Fabrication of Wolter-I grazing mirror[J]. Optics and Precision Engineering, 2011, 19(4): 743

    [6] MENG Yan-li, LI Da, CHEN Bo. X-ray anomalous surface scattering on optical surface[J]. Optics and Precision Engineering, 2013, 21(2): 253

    [7] Cui Tiangang, Zhang Hongji, Ma Wensheng, Chen Bo. Improvements of Surface Profile Measuring Device for Wolter Type-I Mirror[J]. Acta Optica Sinica, 2011, 31(4): 412007

    CUI Tian-gang, WANG Yong-gang, MA Dong-mei, MA Wen-sheng, CHEN Bo. Design of online measuring device for surface profile of Wolter Type I mirror[J]. Optics and Precision Engineering, 2010, 18(8): 1801
    Download Citation