• Acta Photonica Sinica
  • Vol. 45, Issue 4, 412005 (2016)
FENG Ming-chun*, XU Liang, JIN Ling, LIU Wen-qing, GAO Min-guang, LI Sheng, LI Xiang-xian, TONG Jing-jing, and LIU Jian-guo
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/gzxb20164504.0412005 Cite this Article
    FENG Ming-chun, XU Liang, JIN Ling, LIU Wen-qing, GAO Min-guang, LI Sheng, LI Xiang-xian, TONG Jing-jing, LIU Jian-guo. Tilt and Dynamic Alignment for the Moving Mirror in the Fourier Transform Infrared Spectrometer[J]. Acta Photonica Sinica, 2016, 45(4): 412005 Copy Citation Text show less
    References

    [1] XIANGLI Bin,YANG Jian-feng,GAO Zhan,et al.On the tolerance of the mirror tilting in Fourier transform interferometer[J].Acta Photonica Sinica, 1997, 26(2): 132-135.

    [2] ZENG Li-bo, YIN Bang-sheng, HE Bing, et al. Error analysis of moving mirror in Fourier transform interferometer[J].Optics and Precision Engineering, 2006, 14(2): 191-196.

    [4] KATTI P K, SINGTH K. A note on the surface accuracy and alignment of the end mirrors in a michelson interferometer[J].Applied Optics, 1966, 5(12): 1962-1964.

    [5] KAUPPINEN J K, SALOMAA I K, PARTANEN J O.Carouselinterferometer[J].Applied Optics, 1995, 34(27): 6081-6085.

    [6] GRIFFITHS P R, HASETH J A. Fourier transform infrared spectrometry, Second Edition[M]. New York: Wiley&Sons, 2007.

    [7] YU Li-min, DAI Zuo-xiao, WANG Mo-chang, et al. Adapative aligement of fixed mirror by phase detection[J].Optics and Precision Engineering, 2003, 11(5): 448-452.

    [8] KUANG Cui-fang, FENG Qi-bo, FENG Jun-yan, et al.Analyzing characteristic of the four-quadrant detector applied to laser alignment[J].Optical Technique, 2004, 30(4): 387-389.

    [9] AN Kai, WANG Hong-man.A new angle-measurement algorithm of the detector with four quadrants[J].Laser & Infrared, 2001, 31(6): 328-329.

    [10] FENG Long-ling, DENG Ren-liang. Studyon optical tracking with four-quadrant photodetector[J].Infrared and Laser Engeneering, 1996, 25(1): 16-21.

    [11] NORMAN H M, BROBERG H, GIROUXJ, et al. Dynamic alignment design and assessment for scanning interferometers[C].SPIE, 1996, 2832: 126-154.

    [12] YU Li-ming.Adaptive alignment system research of Fourier transform spectrometer[J].Infrared, 2001, 12: 1-11.

    CLP Journals

    [1] HU Yang, XU Liang, LIU Jianguo, JIN Ling, YE Shubin, LI Yakai, HU Rong. Research on Dynamic Cablibration of Fixed Mirror of FTIR Based on Fuzzy Control[J]. Journal of Atmospheric and Environmental Optics, 2018, 13(3): 218

    FENG Ming-chun, XU Liang, JIN Ling, LIU Wen-qing, GAO Min-guang, LI Sheng, LI Xiang-xian, TONG Jing-jing, LIU Jian-guo. Tilt and Dynamic Alignment for the Moving Mirror in the Fourier Transform Infrared Spectrometer[J]. Acta Photonica Sinica, 2016, 45(4): 412005
    Download Citation