• Optoelectronics Letters
  • Vol. 8, Issue 4, 314 (2012)
Fu-ru ZHONG1, Xiao-lin MA2, Xiao-yi Lü3, and Zhen-hong JIA3、*
Author Affiliations
  • 1School of Chemistry and Chemical Engineering, Xinjiang University, Urumqi 830046, China
  • 2College of Life Sciences and Technology, Xinjiang University, Urumqi 830046, China
  • 3College of Information Science and Engineering, Xinjiang University, Urumqi 830046, China
  • show less
    DOI: 10.1007/s11801-012-2244-3 Cite this Article
    ZHONG Fu-ru, MA Xiao-lin, Lü Xiao-yi, JIA Zhen-hong. Label-free quantitative detection using porous silicon as optical biosensor[J]. Optoelectronics Letters, 2012, 8(4): 314 Copy Citation Text show less

    Abstract

    The single-layer porous silicon is prepared by electrochemistry etching method, which is used as an immunosensor for determining recombinant mouse zona pellucida 3 fusion protein (r-mZP3) by Raman spectroscopy analysis at room temperature. The molecule binding increases the effective optical thickness (EOT), and thus the Raman spectrum intensity decreases. The concentration and variation of Raman intensity show a good linear quantitative relation. The excellent sensing performance could open the way to a new family of optical sensors for biological standardization.
    ZHONG Fu-ru, MA Xiao-lin, Lü Xiao-yi, JIA Zhen-hong. Label-free quantitative detection using porous silicon as optical biosensor[J]. Optoelectronics Letters, 2012, 8(4): 314