• Chinese Optics Letters
  • Vol. 6, Issue 5, 377 (2008)
Meimei Kong*, Zhishan Gao, Lei Chen, and Xinhua Li
Author Affiliations
  • School of Electronic Engineering and Optoelectronic Techniques, Nanjing University of Science and Technology, Nanjing 2100942 School of Optometry and Ophthalmology, Jinling Institute of Technology, Nanjing 210001
  • show less
    DOI: Cite this Article Set citation alerts
    Meimei Kong, Zhishan Gao, Lei Chen, Xinhua Li. Effect of crystalline lens surfaces and refractive index on image quality by model simulation analysis[J]. Chinese Optics Letters, 2008, 6(5): 377 Copy Citation Text show less
    References

    [1] P. G. Gobbi, F. Carones, and R. Brancato, Proc. SPIE 3591, 10 (1999).

    [2] Z. Gao, M. Kong, X. Li, L. Chen, and R. Zhu, Chin. Opt. Lett. 4, 299 (2006).

    [3] E. J. Cohen, Ophthalmology 106, 1628 (1999).

    [4] F. H. M. Jongsma, J. de Brabander, and F. Hendrikse, Lasers Med. Sci. 14, 2 (1999).

    [5] Y. Mejía-Barbosa and D. Malacara-Hernández, Optom. Vis. Sci. 78, 240 (2001).

    [6] Q. Li, Q. Ren, W. Li, and Y. Zhu, Laser and Optoelectron. Prog. (in Chinese) 41, (1) 28 (2004).

    [7] G. Smith, Clin. Exp. Optom. 86, 3 (2003).

    [8] J. F. Koretz, C. A. Cook, and P. L. Kaufman, J. Opt. Soc. Am. A 19, 144 (2002).

    [9] M. Dubbelman, G. L. Van der Heijde, and H. A. Weeber, Vision Res. 45, 117 (2005).

    [10] W. Lotmar, J. Opt. Soc. Am. 61, 1522 (1971).

    [11] J. W. Blaker, J. Opt. Soc. Am. 70, 220 (1980).

    [12] A. C. Kooijman, J. Opt. Soc. Am. 73, 1544 (1983).

    [13] R. Navarro, J. Santamaria, and J. Bescos, J. Opt. Soc. Am. A 2, 1273 (1985).

    [14] I. Escudero-Sanz and R. Navarro, J. Opt. Soc. Am. A 16, 1881 (1999).

    [15] H. Liou and N. A. Bennan, J. Opt. Soc. Am. A 14, 1684 (1997).

    [16] ZEMAX Development Corporation, ZEMAX Optical Design Program User’s Guide, 136 (2003).

    [17] D. Siedlecki, H. Kasprzak, and B. K. Pierscionek, Opt. Lett. 29, 1197 (2004).

    [18] Y. Liu, Z. Fang, and Z. Wang, Acta Opt. Sin. (in Chinese) 25, 136 (2005).

    [19] A. P. Masajada, Ophthal. Physiol. Opt. 19, 41 (1999).

    [20] D. A. Atchison and G. Smith, Vision Res. 35, 2529 (1995).

    [21] D. T. Moore, J. Opt. Soc. Am. 61, 886 (1971).

    [22] Z. Sun and Q. Wang, Chin. J. Optom. Ophthalm. (in Chinese) 9, 66 (2007).

    CLP Journals

    [1] Yayan Bian, Yongji Liu, Lai Jiang. Design of double-zone aspheric diffractive intraocular lens with extended depth of focus[J]. Chinese Optics Letters, 2018, 16(9): 093301

    [2] Xueyong Zhang, Jianguo Ma, Rongsheng Lu, Yibao Li, Zhen Tang, Guohong Liu. Development of an optical probe to measure the flattened area of ocular cornea[J]. Chinese Optics Letters, 2010, 8(1): 103

    Meimei Kong, Zhishan Gao, Lei Chen, Xinhua Li. Effect of crystalline lens surfaces and refractive index on image quality by model simulation analysis[J]. Chinese Optics Letters, 2008, 6(5): 377
    Download Citation