• Acta Photonica Sinica
  • Vol. 40, Issue 8, 1261 (2011)
LIU Zhi-ying1、*, SONG Yu-long2, FU Yue-gang1, and GAO Tian-yuan1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/gzxb20114008.1261 Cite this Article
    LIU Zhi-ying, SONG Yu-long, FU Yue-gang, GAO Tian-yuan. Tolerance Analysis of Stitching System Based on Equivalent Nodal Point[J]. Acta Photonica Sinica, 2011, 40(8): 1261 Copy Citation Text show less

    Abstract

    In sub-aperture stitching system, image quality will be affected directly by tilt and shift errors of sub-apertures. The equivalent nodal point concept of dynamic optics was applied. During alignment of sub-aperture stitching system, if the sub-aperture was tilted and shifted, the circle center of sub-aperture would be tilted and shifted consequently. The equivalent nodal point will shift would sub-apertures. The spot size variation due to sub-apertures image displacement was analyzed in detail. The effect of sub-aperture tilt and shift on image quality in stitching system was simplified with equivalent nodal point concept. Through application in structure design and tolerance analysis of sub-aperture stitching prototype, the tilt tolerance and displacement tolerance is 4 μrad and 6 μm respectively. Consequently the alignment tolerance was controlled effectly in stiching prototype.
    LIU Zhi-ying, SONG Yu-long, FU Yue-gang, GAO Tian-yuan. Tolerance Analysis of Stitching System Based on Equivalent Nodal Point[J]. Acta Photonica Sinica, 2011, 40(8): 1261
    Download Citation