• Acta Photonica Sinica
  • Vol. 49, Issue 12, 42 (2020)
Xue ZOU, Ou DENG, Bin-bin LUO*, De-cao WU, Ming-fu ZHAO, Nian-bing ZHONG, Tao SONG, Shang-hai JIANG, Lang XIE, Peng LIU, and En-hua LIU
Author Affiliations
  • Chongqing Key Laboratory of Optical Fiber Sensor and Photoelectric Detection,Chongqing University of Technology,Chongqing400054,China
  • show less
    DOI: 10.3788/gzxb20204912.1206002 Cite this Article
    Xue ZOU, Ou DENG, Bin-bin LUO, De-cao WU, Ming-fu ZHAO, Nian-bing ZHONG, Tao SONG, Shang-hai JIANG, Lang XIE, Peng LIU, En-hua LIU. Research on the Performance of Cantilever Low Frequency Vibration Sensor Based on Thin-diameter Excessively Tilted Fiber Grating[J]. Acta Photonica Sinica, 2020, 49(12): 42 Copy Citation Text show less
    References

    [1] S T VOHRA, G A JOHNSON, M D TODD. Distributed strain monitoring with arrays of fiber Bragg grating sensors on an in-Construction steel box-girder bridge, 83, 454-461(2000).

    [2] Z ZHAO, Z LIU, M TANG. Robust in-fiber spatial interferometer using multicore fiber for vibration detection. Optics Express, 26, 29629-29637(2018).

    [3] Zhen-long CHENG, Jian-lin ZHAO, Wang-min ZHOU. A vibration sensor based on fiber Bragg grating Fabry-Perot cavity. Acta Photonica Sinica, 39, 47-52(2010).

    [4] H TSUDA. Fiber Bragg grating vibration-sensing system, insensitive to Bragg wavelength and employing fiber ring laser. Optics Letters, 35, 2349-2351(2010).

    [5] T GUO, L SHANG, Y RAN. Fiber-optic vector vibroscope. Optics Letters, 37, 2703-2705(2012).

    [6] Q RONG, X QIAO, T GUO. Orientation-dependent fiber-optic accelerometer based on grating inscription over fiber cladding. Optics Letters, 39, 6616-6619(2014).

    [7] S TANAKA, H SOMATOMO, A WADA. Fiber-optic mechanical vibration sensor using long-period fiber grating. Japanese Journal of Applied Physics, 48, 07(2009).

    [8] K ZHOU, L ZHANG, X CHEN. Optic sensors of high refractive-index responsivity and low thermal cross sensitivity that use fiber Bragg gratings of >80 tilted structures. Optics Letters, 31, 1193-1195(2006).

    [9] Z YAN, Q SUN, C WANG. Refractive index and temperature sensitivity characterization of excessively tilted fiber grating. Optics Express, 25, 3336-3346(2017).

    [10] X CHEN, K ZHOU, L ZHANG. In-fiber twist sensor based on a fiber Bragg grating with 81°tilted structure. IEEE Photonics Technology Letters, 18, 2596-2598(2006).

    [11] C MOU, K ZHOU, Z YAN. Liquid level sensor based on an excessively tilted fibre grating. Optics Communications, 305, 271-275(2013).

    [12] Bin-bin LUO, Wen-gen ZOU, Ming-fu ZHAO. pH sensor based on fiber grating with extremely large tilt angle and its sensitivity enhancement. Acta Optica Sinica, 37, 113-120(2017).

    [13] T LU, Y SUN, Y MORENO. Excessively tilted fiber grating-based vector magnetometer. Optics Letters, 44, 2494-2497(2019).

    [14] B LUO, W YANG, X HU. Study on vibration sensing performance of an equal strength cantilever beam based on an excessively tilted fiber grating. Applied Optics, 57, 2128-2134(2018).

    [16] Bin-bin LUO, Lang XIE, Ya-jie WANG. Performance optimization of excessively tilted fiber grating cantilever beam vibration sensor. Acta Optica Sinica, 39, 0806006(2019).

    [17] Z YAN, Z SUN, K ZHOU. Numerical and experimental analysis of sensitivity-enhanced RI sensor based on ExTFG in thin cladding fiber. Journal of Lightwave Technology, 33, 3023-3027(2015).

    [18] X W SHU, L ZHANG, I BENNION. Sensitivity characteristics of long-period fiber gratings. Journal of Lightwave Technology, 20, 255-266(2002).

    Xue ZOU, Ou DENG, Bin-bin LUO, De-cao WU, Ming-fu ZHAO, Nian-bing ZHONG, Tao SONG, Shang-hai JIANG, Lang XIE, Peng LIU, En-hua LIU. Research on the Performance of Cantilever Low Frequency Vibration Sensor Based on Thin-diameter Excessively Tilted Fiber Grating[J]. Acta Photonica Sinica, 2020, 49(12): 42
    Download Citation