• Acta Photonica Sinica
  • Vol. 42, Issue 12, 1496 (2013)
LUO Yongjun* and MOU Tongsheng
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/gzxb20134212.1496 Cite this Article
    LUO Yongjun, MOU Tongsheng. Design of a Weighted Radiance of the LED Measuring System[J]. Acta Photonica Sinica, 2013, 42(12): 1496 Copy Citation Text show less
    References

    [1] RZ.ANOWSKA M, SARNA T. Lightinduced damage to the retina: role of rhodopsin chromophore revisited[J]. Photochemistry and Photobiology, 2005, 81(6): 1305-1330.

    [2] SANDER M, MLLER M, TETZ M R. Possible retina damage potential of the femtosecond laser in situ keratomileusis (fsLASIK) refractive surgery[J]. Medical Laser Application, 2008, 23(1): 39-45.

    [3] ZHANG Y, KORNHAUSER J M, ZEE P C, et al. Effects of aging on lightinduced phaseshifting of circadian behavioral rhythms, Fos expression and CREB phosphorylation in the hamster suprachiasmatic nucleus[J]. Neuroscience, 1996, 70(4): 951-961.

    [4] SLINEY D, ARONROSA D, DELORI F, et al. Adjustment of guidelines for exposure of the eye to optical radiation from ocular instruments: statement from a task group of the International Commission on NonIonizing Radiation Protection (ICNIRP)[J]. Applied Optics, 2005, 44(11): 2162-2176.

    [5] ROBERTS J E. Ocular phototoxicity[J]. Journal of Photochemistry and Photobiology, 2001, 64(2): 136-143.

    [6] CHENG L, SUNS, CHUC, et al. The effects of the bacterial interaction with visiblelight responsive titania photocatalyst on the bactericidal performance[J]. Journal of Biomedical Science, 2009, 16(1): 7-7.

    [7] SLINEY D H. Optical radiation safety of medical light sources[J]. Physics in Medicine and Biology, 1997, 42(5): 981-981.

    [8] KOHMOTO K. Evaluation of actual light sources with proposed photobiological lamp safety standard and its applicability to guide on lighted environment[J].Publicationscommission Internationale de Leclairage cie, 1999, 133(2): 305-309.

    [9] BOZKURT A, ONARAL B. Safety assessment of near infrared light emitting diodes for diffuse optical measurements[J]. BioMedical Engineering OnLine, 2004, 3(1): 9-9.

    [10] VOS J J, NORREN D. Retinal damage by optical radiation. An alternative to current, ACGIH‐inspired guidelines[J]. Clinical and Experimental Optometry, 2005, 88(4): 200-211.

    [11] ZHAO S, WANG K, CHEN F, et al. Lens design of LED searchlight of high brightness and distant spot[J]. JOSA A, 2011, 28(5): 815820.

    [12] DELORI F C, WEBB R H, SLINEY D H. Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices[J]. Journal of the Optical Society of American A, 2007, 24(5): 1250-1265.

    [13] SU Xiuqin, WANG Fei, LIU Wen. A new method for accelerating the speedof processing the data collected by CCD[J]. Acta Photonica Sinica, 2001, 30(7): 864-867.

    [14] CAMPOS J. Radiometric calibration of chargecoupleddevice video cameras[J]. Metrología, 2000, 37(5): 459-459.

    [15] QIAO Naosheng. Nonlinearity of CCD and its adjustment[J]. Acta Photonica Sinica,2008, 37(11): 2305-2309.

    [16] WANG Yiqun, YAN Changxiang, JIA Ping. Motion precision measurement of imaging spectrometer's scanning mirror[J].Acta Photonica Sinica, 2012, 41(2): 185-185.

    CLP Journals

    [1] LIU Shi, ZHANG Guo-yu, SUN Gao-fei, WANG Ling-yun, GAO Yu-jun. Design of the Moon Simulator with Large Diameter Based on LightTools and Precision Analysis[J]. Acta Photonica Sinica, 2015, 44(9): 922002

    LUO Yongjun, MOU Tongsheng. Design of a Weighted Radiance of the LED Measuring System[J]. Acta Photonica Sinica, 2013, 42(12): 1496
    Download Citation