• Chinese Journal of Lasers
  • Vol. 38, Issue 12, 1216002 (2011)
Wang Chunhui1、*, Ji Yiqin2, Gao Long1, Li Yanchao1, and Qu Yang1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/cjl201138.1216002 Cite this Article Set citation alerts
    Wang Chunhui, Ji Yiqin, Gao Long, Li Yanchao, Qu Yang. Optical Design of Large Working Area f-θ Scanning Lens for 2 μm Laser Heterodyne Interferometry System[J]. Chinese Journal of Lasers, 2011, 38(12): 1216002 Copy Citation Text show less
    References

    [1] M. A. Arain, N. A. Riza. Fiber-coupled in-line heterodyne optical interferometer for minimally invasive sensing[J]. J. Lightwave Technol., 2005, 23(8): 2449~2454

    [2] Liu Zhaodong, Yu Lina, Han Zhigang et al.. Measurement of the wavefront collimation of a large aperture near-infrared interferometer using a scanning pentaprism system[J]. Chinese J. Lasers, 2010, 37(4): 1082~1087

    [3] Wang Meng, Liu Tiegen, Wang Bo et al.. Research on laser physical and chemical modification of metal complex[J]. Chinese J. Lasers, 2010, 37(12): 3155~3161

    [4] Song Nanhai, Meng Yonggang, Lin Jing. Flying-height measurement with a symmetrical common-path heterodyne interferometry method[J]. IEEE Trans. Magn., 2010, 46(3): 928~932

    [5] B. K. A. Ngoi, K. Venkatakrishnan, B. Tan. Laser scanning heterodyne-interferometer for micro-components[J]. Opt. Commun., 2000, 173(1-6): 291~301

    [6] K. H. Chen, W. Y. Chang, J. H. Chen. Measurement of the pretilt angle and the cell gap of nematic liquid crystal cells by heterodyne interferometry[J]. Opt. Express, 2009, 17(16): 14143~14149

    [7] Ge Baozhen, Li Xiaojie, Qiu Shi. Camera lens distortion correction based on coplanar point direct liner transformation[J]. Chinese J. Lasers, 2010, 37(2): 488~494

    [8] Y. U. Nam, M. S. Cheon, J. H. Ha et al.. Improved common-path fast-scanning heterodyne interferometer system as potential dense-plasma diagnostics[J]. Rev. Sci. Instrum., 2004, 75(10): 3417~3419

    [9] Ji Yiqun, Shen Weimin. Optical design of large working area F-Theta lens[J]. Acta Optica Sinica, 2005, 25(11): 1539~1542

    [10] C. M. Wen, K. W. Yuan, P. T. Chou et al.. An f-theta lens design for bio-medical system: laser scanning microarray reader[J]. Opt. Quantm. Electron., 2006, 37(13-15): 1367~1376

    [11] D. J. Johnson. Micromirror for laser-beam scanning for robotics and other applications[C]. 2nd International Conference on Autonomous and Agents, 2004. 408~412

    [12] Ji Rongyi, Zhao Changming, Chen Guo. Analysis and calculation of scan trance of laser scanning roration mirror[J]. Chinese J. Lasers, 2011, 38(4): 0408003

    CLP Journals

    [1] Qu Yang, Wang Chunhui, Pang Yajun, Tang Tiantian. Vibration Performance Researching in the MEMS Galvanometer of an Imaging Lidar System[J]. Acta Optica Sinica, 2014, 34(s1): 111004

    Wang Chunhui, Ji Yiqin, Gao Long, Li Yanchao, Qu Yang. Optical Design of Large Working Area f-θ Scanning Lens for 2 μm Laser Heterodyne Interferometry System[J]. Chinese Journal of Lasers, 2011, 38(12): 1216002
    Download Citation