• Chinese Optics Letters
  • Vol. 11, Issue 3, 031701 (2013)
Guozhong Liu and Ruikang Wang
DOI: 10.3788/col201311.031701 Cite this Article Set citation alerts
Guozhong Liu, Ruikang Wang. Stripe motion artifact suppression in phase-resolved OCT blood flow images of the human eye based on the frequency rejection filter[J]. Chinese Optics Letters, 2013, 11(3): 031701 Copy Citation Text show less
References

[1] D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Pauliafito, and J. G. Fujimoto, Science 254, 1178 (1991).

[2] A. F. Fercher, W. Drexler, C. K. Hitzenberger, and T. Lasser, Rep. Prog. Phys. 66, 239 (2003).

[3] J. S. Schuman, C. A. Puliafito, and J. G. Fujimoto, Optical Coherence Tomography of Ocular Diseases, 2nd ed. (Slack, Thorofare, 2004).

[4] Y. Zhao, Z. Chen, C. Saxer, S. Xiang, J. F. de Boer, and J. S. Nelson, Opt. Lett. 25, 114 (2005).

[5] J. Zhang and Z. P. Chen, Opt. Express 13, 7449 (2005).

[6] R. K. Wang, S. L. Jacques, Z. H. Ma, S. Hanson, and A. Gruber, Opt. Express 15, 4083 (2007).

[7] R. A. Leitgeb, L. Schmetterer, W. Drexler, A. F. Fercher, R. J. Zawadzki, and T. Bajraszewski, Opt. Express 11, 3116 (2003).

[8] B. J. Vakoc, S. H. Yun, J. F. de Boer, G. J. Tearney, and B. E. Bouma, Opt. Express 13, 5483 (2005).

[9] S. Ricco, M. Chen, H. Ishikawa, G. Wollstein, and J. Schuman, in Proceedings of Medical Image Computing and Computer-Assisted Intervention2009 100 (2009).

[10] M. F. Kraus, B. Potsaid, M. A. Mayer, R. Bock, B. Baumann, J. J. Liu, J. Hornegger, and J. G. Fujimoto, Biomed. Opt. Express 3, 1182 (2012).

[11] E. A. Swanson, J. A. Izatt, M. R. Hee, D. Huang, C. P. Lin, J. S. Schuman, C. A. Puliafito, and J. G. Fujimoto, Opt. Lett. 18, 1864 (1993).

[12] R. J. Zawadzki, A. R. Fuller, S. S. Choi, D. F. Wiley, B. Hamann, and J. S. Werner, Proc. SPIE 6426, 642607 (2007).

[13] T. M. Jorgensen and B. Sander, Proc. SPIE 6426, 642608 (2007).

[14] R. D. Ferguson, D. X. Hammer, L. A. Paunescu, S. Beaton, and J. S. Schuman, Opt. Lett. 29, 2139 (2004).

[15] D. X. Hammer, R. D. Ferguson, J. C. Magill, L. A. Paunescu, S. Beaton, H. Ishikawa, G. Wollstein, and J. S. Schuman, J. Biomed. Opt. 10, 024038 (2005).

[16] D. Sacchet, M. Brzezinski, J. Moreau, P. Georges, and A. Dubois, Appl. Opt. 49, 1480 (2010).

[17] D. Lin, X. Jiang, F. Xie, W. Zhang, L. Zhang, and I. Bennion, Opt. Express 12, 5729 (2004).

[18] Z. Yaqoob, W. Choi, S. Oh, N. Lue, Y. Park, C. Fang-Yen, R. R. Dasari, K. Badizadegan, and M. S. Feld, Opt. Express 17, 10681 (2009).

[19] P. H. Tomlins and R. K. Wang, Meas. Sci. Technol. 18, 3365 (2007).

[20] T. S. Ralston, D. L. Marks, P. S. Carney, and S. A. Boppart, in Proceedings of 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro 578 (2006).

[21] L. An and R. K. Wang, Opt. Express 16, 11438 (2008).

[22] L. An, J. Qin, and R. K. Wang, Opt. Express 18, 8220 (2010).

[23] T. Schmoll, A. S. G. Singh, C. Blatter, S. Schriefl, C. Ahlers, U. Schmidt-Erfurth, and R. A. Leitgeb, Biomed. Opt. Express 2, 1159 (2011).

CLP Journals

[1] Jiawei Mei, Xiaosheng Xiao, Changxi Yang. 1  μm wavelength swept fiber laser based on dispersion-tuning technique[J]. Chinese Optics Letters, 2015, 13(9): 091403

Data from CrossRef

[1] Haijiao He, Guozhong Liu, Peng Mo, Bo Li, JiaLun Wu, XiangYou Ding. Correction of motion artifact in 3D retinal optical coherence tomography imaging. 2013 6th International Congress on Image and Signal Processing (CISP), 261(2013).

[2] Roberto Reif, Utku Baran, Ruikang K. Wang. Motion artifact and background noise suppression on optical microangiography frames using a na?ve Bayes mask. Applied Optics, 53, 4164(2014).

[3] Guozhong Liu, Zhehai Zhou, Ping Li. Phase registration based on matching of phase distribution characteristics and its application in FDOCT. Optics Express, 21, 13241(2013).

[4] Kristin M. Poole, Devin R. McCormack, Chetan A. Patil, Craig L. Duvall, Melissa C. Skala. Quantifying the vascular response to ischemia with speckle variance optical coherence tomography. Biomedical Optics Express, 5, 4118(2014).

[5] Raksha Raghunathan, Chih‐Hao Liu, Amur Kouka, Manmohan Singh, Rajesh C. Miranda, Kirill V. Larin. Assessing the acute effects of prenatal synthetic cannabinoid exposure on murine fetal brain vasculature using optical coherence tomography. Journal of Biophotonics, e201900050(2019).

Guozhong Liu, Ruikang Wang. Stripe motion artifact suppression in phase-resolved OCT blood flow images of the human eye based on the frequency rejection filter[J]. Chinese Optics Letters, 2013, 11(3): 031701
Download Citation