[1] FAN X,WHITE I M ,SHOPOVA S I ,et al. Sensitive optical biosensors for unlabeled targets:A review[J].Analytica Chimica Acta,2008,620:8-26.
[2] CHAO C Y,GUO L J. Design and optimization of microring resonators in biochemical sensing applications[J]. Journal of Lightwave Technology,2006,24(3):1395-1402.
[3] CHAO C Y ,FUNG W,GUO L J. Polymer microring resonators for biochemical sensing applications[J].IEEE Journal of Selected Topics in Quantum Electronics,2006,12(1):134-142.
[4] ZOU Ren-ling,CHEN Bao-xue,WANG You-you,et al. Biochemical solution concentration sensing using stripe waveguides based on ion exchange technology[J].Acta Photonica Sinica,2012,41(2):150-153.
[5] TERREL M,DIGONNET M J F,FAN S H. Ring-coupled Mach-Zehn-der interferometer optimized for sensing[J]. Applied Optics,2009,48(26):4874-4878.
[6] ZHANG Qi,ZHOU Jun,CHEN Jin-ping,et al. Temperature sensing characteristics of all-fiber Mach-Zehnder interferometer based on Bitaper-LPFG-Bitaper Structure[J].Acta Photonica Sinica,2012,42(3):308-310.
[7] RINDORF L,JENSEN J B. Photonic crystal fiber long-period gratings for biochemical sensing[J].Optics Express,2006,14(18):8224-8231.
[8] HE Zhong-jiao. Characteristics of photonic crystal biber for hydraulic pressure sensing[J].Acta Photonica Sinica,2012,41(3):317-319.
[9] PRASAD T,MITTLEMAN D M,COLVIN V L. A photonic crystal sensor based on the superprism effect[J].Optical Materials,2006,29(1):56 -59.
[10] YI Hua-xiang,CITRIN D S,ZHOU Zhi-ping. Highly sensitive silicon microring sensor with sharp asymmetrical resonance[J]. Optics Express,2010,18(3):2967-2971.
[11] VOS K D,BARTOLOZZI I,SCHACHT E,et al. Silicon-on-Insulator microring resonator for sensitive and label-free biosensing [J]. Optics Express,2007,15(12):7610-7615.
[12] BOYD R W,HEEBNER J E. Sensitive disk resonator photonic biosensor[J].Applied Optics,2001,40(31):5742-5746.
[13] ZHANG Xiao-bei,HUANG De-xin,ZHANG Xin-liang. Transmissi -on characteristics of dual microring resonators coupled via 3×3 couplers[J].Optics Express,2007,15(21):13557-13573.
[14] XIA F,SEKARIC L,VLASOV Y. A mode conversion losses in silicon-on-insulator photonic wire based racetrack resonators[J].Optics Express, 2006,14(9):3872-3886.
[15] ZHOU Lin-jie,POON A W. Electrically reconfigurable silicon microring reaonator-based filter with waveguide-coupled feedback[J].Optics Express,2007,15(15):9196-9197.
[16] YI Hua-xiang,CITRIN D S,ZHOU Zhi-ping. Coupling-induced high-sensitivity silicon microring intensity-based sensor[J]. Journal of Optical Society in America B,2011,28(7):1611-1615.
[17] FAN S. Sharp asymmetric line shapes in side-coupled waveguide-cavity systems [J]. Applied Physics Letters,2002,80(6):908-910.
[18] CHAO C Y. Biochemical sensors based on polymer microrings with sharp asymmetrical resonance[J].Applied Physics Letters,83(8):1527.
[19] LU Ying,FU Xiang-yong,et al. Fano resonance and spectral compression in a ring resonator dropfilter with feedback[J]. Optics Communications,2011,284(1):476-479.
[20] HAUS H A,HUANG W P,KAWAKAMI S,et al. Coupled mode theory of optical waveguides[J].Journal of Lightwave Technology,1987,5(1):16-23.
[21] CAPMANY J,MURIEL M A. A new transfer matrix formalism for the analysis of fiber ring resonators:compound coupled structures for FDMA demuliplexing[J]. Journal of Lightwave Technology,1990,8(12):1904-1919.
[22] KINROT N. Investigation of a periodically segmented waveguide Fabry-Perot interferometer for use as a chemical/biosensor [J]. Journal of Lightwave Technology,2006,24(5):2139-2143.