• Chinese Journal of Lasers
  • Vol. 38, Issue 10, 1008003 (2011)
Lu Weiye*, Lu Jidong, Yao Shunchun, and Chen Kai
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/cjl201138.1008003 Cite this Article Set citation alerts
    Lu Weiye, Lu Jidong, Yao Shunchun, Chen Kai. Synchronization Detection of Nitrogen Phosphorus Potassium in Compound Fertilizer with Laser Induced Breakdown Spectroscopy[J]. Chinese Journal of Lasers, 2011, 38(10): 1008003 Copy Citation Text show less

    Abstract

    The laser induced breakdown spectroscopy (LIBS) has been used to synchronized detection the concentration of nitrogen, phosphorus, potassium in compound fertilizers. Applied the partial least squares (PLS) method on 10 selected samples which are known as the calibration samples to establish quantitative analysis regression models of different components. Then, use 5 untested samples to test the result of quantitative analysis regression models. Finally compare the predictive value with the reference obtained by the conventional inductively coupled plasma atomic emission spectrometry (ICP-AES) method. The result shows that the average relative errors (REP) are less than 8% mass fraction. The relative standard deviation (RSD) is less than 7% mass fraction. The detection limits (LOD) are 0.16%, 0.21% and 0.50% mass fraction. The experimental verify the applicability of the laser induced breakdown spectroscopy in synchronization rapid and accurate measurement of the three major fertilizer nutrients.
    Lu Weiye, Lu Jidong, Yao Shunchun, Chen Kai. Synchronization Detection of Nitrogen Phosphorus Potassium in Compound Fertilizer with Laser Induced Breakdown Spectroscopy[J]. Chinese Journal of Lasers, 2011, 38(10): 1008003
    Download Citation