• Spectroscopy and Spectral Analysis
  • Vol. 37, Issue 2, 368 (2017)
SUN Yuan-cheng*, SONG Xue-fu, DU Xiu-rong, ZHANG Xiao-qiang, and WANG Hui
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3964/j.issn.1000-0593(2017)02-0368-06 Cite this Article
    SUN Yuan-cheng, SONG Xue-fu, DU Xiu-rong, ZHANG Xiao-qiang, WANG Hui. Spectroscopic Diagnosis of Atmosphere High Frequency Air Plasma Electron Temperature[J]. Spectroscopy and Spectral Analysis, 2017, 37(2): 368 Copy Citation Text show less

    Abstract

    Atmosphere high frequency plasma is widely used due to its advantages of free of electrode pollution, high energy density high temperature and controllable redox conditions. As the key parameter in practical use, electron temperature of plasma is commonly diagnosed with atomic emission spectroscopy and calculated with Boltzmann plots. But electron temperatures calculated based on different lines by different researchers are usually not comparable due to transition probability data, application environment, instrumental error and data processing. This paper discussed influences of element and spectral range on calculated electron temperature for the first time in order to obtain reliable electron temperature of atmosphere high frequency air plasma. 7-channel high resolution fiber spectrometer with measurement range of 200~1 077 nm was used to test atomic emission spectroscopy. The experiment indicates that: The R square of fitted slope is 095 and standard deviation is the lowest using N Ⅰ lines in 738~940 nm and the calculated electron temperature is the most reliable; electron temperature calculated with Si and O lines are unreliable because they are easily binding to heavy SiO2 particles; reliable electron temperature also cannot be obtained by mixed Ar lines.
    SUN Yuan-cheng, SONG Xue-fu, DU Xiu-rong, ZHANG Xiao-qiang, WANG Hui. Spectroscopic Diagnosis of Atmosphere High Frequency Air Plasma Electron Temperature[J]. Spectroscopy and Spectral Analysis, 2017, 37(2): 368
    Download Citation