• Acta Photonica Sinica
  • Vol. 44, Issue 5, 522004 (2015)
GUO Xin1、2、*, ZHANG Wei1、2, SU Jin-hui1、2, YANG Bo1、2, and WAN Xin-jun1、2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/gzxb20154405.0522004 Cite this Article
    GUO Xin, ZHANG Wei, SU Jin-hui, YANG Bo, WAN Xin-jun. Design of a Focus-tunable Capsule Endoscope System[J]. Acta Photonica Sinica, 2015, 44(5): 522004 Copy Citation Text show less
    References

    [1] ZHANG Yan-hui, HUANG Zhan-hua. The progress of capsule endoscope technology[J]. Modern Instruments, 2006, (04): 4-7.

    [2] MERON G D. The development of the swallowable video capsule(M2A)[J]. Gastrointestinal Endoscopy, 2000, 52(6): 817-819.

    [3] AKI T. Olympus medical system to market capsule endoscope in Europe[J]. JCNN News Summaries-Japan Corporate News Network, 2005, 1.

    [4] PARK H J, NAM H W, SONG B S, et al. Design of bi-directional and multi-channel miniaturized telemetry module for wireless endoscopy[C].2ND Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medical&Biology. Wisconsic, 2002: 273-276.

    [5] LI Chen-yi, ZHANG Bing-ling, CHEN Chun-xiao, et al. OMOM capsule endoscopy in diagnosis of small bowel disease[J]. Journal of Zhejiang University Science B, 2008, 9(11): 857-862.

    [6] XIE Xiang, LI Guo-lin, ZHANG Chun, et al. Design of bi-direction digital and miniaturized wireless endoscopy system[J].Research &Progress of SSE,2007, 27(01): 123-128.

    [7] FANG Yi-chen, TSAI Cheng-mu, CHUNG Cheng-lun. A study of optical design and optimization of zoom optics with liquid lenses through modified genetic algorithm[J]. Optics Express, 2011, 19(17): 16291-16302.

    [8] ZHANG Wei, LI Dan, GUO Xin. Optical design and optimization of a micro zoom system with liquid lenses[J]. Journal of the Optical Society of Korea, 2013, 17(5): 447-453.

    [9] ZHANG Wei, TIAN Wei-jian, ZHANG Hong-jian. A method of bifocal endoscope system design[J]. Acta Photonica Sinica, 2010, 39(1): 105-109.

    [10] KUIPER S, HENDRIKS B H W. Variable-focus liquid lens for miniature cameras[J]. Applied Physics Letters, 2009, 85(7): 1128-1130.

    [11] REN H, FAN Y, GAUZA S, et al. Tunable-focus flat liquid crystal spherical lens[J]. Applied Physics Letters, 2009, 84(23): 4789-4791.

    [12] REN H, DAVID F, ANDERSON P A, et al. Tunable-focus liquid lens controlled using a servo motor[J]. Optics Express, 2006, 14(18): 8031-8036.

    [13] NGUYEN B K, KIYOSHI M, ISAO S. Polymer thin filmdeposited on liquid for varifocal encapsulated liquid lens[J]. Applied Physics Letters, 2008, 93(12): 124101.

    [14] ZHANG Zhan-wen, LI Bo, WANG Chao-yang, et al. Preparation of parylene film by vapor deposition[J]. Materials Review, 2003, 17(6): 86-87+83.

    [15] ZHANG Wei, LIU Peng-fei, WEI Xiao-na, et al. The analysis of the wavefront aberration caused by the gravity of the tunable-focus liquid-filled membrane lens[C]. SPIE, 2010, 7849: 78491W.

    [16] SEIICHI T, HISANORI T, NGUYEN B K, et al. Liquid-phase packaging of a glucose oxidase solution with parylene direct encapsulation and an ultraviolet curing adhesive cover for glucose sensors[J]. Sensors, 2010, 10(6): 5888-5898.

    CLP Journals

    [1] Jia Xiaohang, Zhang Qinyuan, Yan Qinglai, Yang Shiming, Chen Debao. The study of the methods for evaluating the matching rate of capsule endoscope pixels and its resolution effectiveness[J]. Opto-Electronic Engineering, 2019, 46(1): 180112

    GUO Xin, ZHANG Wei, SU Jin-hui, YANG Bo, WAN Xin-jun. Design of a Focus-tunable Capsule Endoscope System[J]. Acta Photonica Sinica, 2015, 44(5): 522004
    Download Citation