• NUCLEAR TECHNIQUES
  • Vol. 47, Issue 2, 020201 (2024)
Yuanying HAN1, Yafeng WU1、*, Lan DONG1、2, Tong WANG1、2, Shang LU1, Luping YAN1, Luyan ZHANG1, Xiaoyang LIU1, Haoyue YAN1, Na MA1、2, Zhenqiang HE1、2, Zhiyong KE1、2, Lingling MEN1、2, Bo LI1、2, Xiaolong WANG1、2, and Jing LIANG1、2
Author Affiliations
  • 1Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
  • 2Dongguan Neutron Science Center, Dongguan 523803, China
  • show less
    DOI: 10.11889/j.0253-3219.2024.hjs.47.020201 Cite this Article
    Yuanying HAN, Yafeng WU, Lan DONG, Tong WANG, Shang LU, Luping YAN, Luyan ZHANG, Xiaoyang LIU, Haoyue YAN, Na MA, Zhenqiang HE, Zhiyong KE, Lingling MEN, Bo LI, Xiaolong WANG, Jing LIANG. Analysis of calibration schemes for HEPS sextupole[J]. NUCLEAR TECHNIQUES, 2024, 47(2): 020201 Copy Citation Text show less
    Snapshot of measuring needle in the punching datum plane
    Fig. 1. Snapshot of measuring needle in the punching datum plane
    User interface of DMIS software for creating the coordinate system
    Fig. 2. User interface of DMIS software for creating the coordinate system
    Snapshot of measuring needle in the pole seam plane
    Fig. 3. Snapshot of measuring needle in the pole seam plane
    Diagram of the calibration of the hexacode iron by laser tracker
    Fig. 4. Diagram of the calibration of the hexacode iron by laser tracker
    Diagram of the calibration of the hexacode iron by 3D CMM
    Fig. 5. Diagram of the calibration of the hexacode iron by 3D CMM
    Diagram of the sextupole model and device coordinates
    Fig. 6. Diagram of the sextupole model and device coordinates

    种类

    Category

    孔径

    Aperture / mm

    极缝距离

    Polar distance / mm

    磁铁长度

    Magnet length / mm

    磁铁高度

    Magnet height / mm

    SF1/2278.0304421
    SD1/43211.6374434
    SD2/3278.0350474
    Table 1. Main mechanical parameters of the sextupole of HEPS ring

    标定重复性

    Repeatability

    ΔX

    / mm

    ΔY

    / mm

    ΔZ

    / mm

    旋转前坐标系

    Pre-rotation coordinate system

    0.0040.0030.004

    旋转后坐标系

    Post-rotation coordinate system

    0.0050.0040.003
    Table 2. Calibration repeatability of the coordinate system before and after rotation of the HEPS sextupole

    磁铁类型

    Magnet type

    最大偏差

    Maximum deviation / mm

    最小偏差

    Minimum deviation / mm

    标准偏差

    Deviation standard / mm

    SF1/20.046-0.0440.012
    SD1/40.053-0.0450.014
    SD2/30.062-0.0810.015
    Table 3. Pole seam deviation statistics of the HEPS sextupoles (63 in total)

    磁铁类型

    Magnet type

    XX-directionYY-direction

    最大偏差

    Maximum deviation / mm

    最小偏差

    Minimum deviation / mm

    标准偏差

    Deviation standard / mm

    最大偏差

    Maximum deviation / mm

    最小偏差

    Minimum deviation / mm

    标准偏差

    Deviation standard / mm

    SF1/20.108-0.1230.0580.047-0.0480.022
    SD1/40.083-0.1460.0650.061-0.0610.028
    SD2/30.214-0.1880.0880.101-0.1000.042
    Table 4. Reference point deviation statistics before and after coordinate system rotation (63 sextupoles)

    磁铁类型

    Magnet type

    最大值

    Maximum value / mrad

    最小值

    Minimum value / mrad

    标准值

    Deviation value / mrad

    SF1/20.315-0.3600.175
    SD1/40.244-0.4310.194
    SD2/30.628-0.5520.264
    Table 5. Statistics of mechanical center deviation before and after coordinate system rotation (63 sextupoles)
    Yuanying HAN, Yafeng WU, Lan DONG, Tong WANG, Shang LU, Luping YAN, Luyan ZHANG, Xiaoyang LIU, Haoyue YAN, Na MA, Zhenqiang HE, Zhiyong KE, Lingling MEN, Bo LI, Xiaolong WANG, Jing LIANG. Analysis of calibration schemes for HEPS sextupole[J]. NUCLEAR TECHNIQUES, 2024, 47(2): 020201
    Download Citation