[1] HUANG J Z. Anti-rust effect and mechanism of hydrophobic functional organic rust inhibitor[D]. Guangzhou: South China University of Technology, 2021 (in Chinese).
[2] CHESS P. Corrosion in reinforced concrete structures[M]//Cathodic Protection of Steel in Concrete and Masonry, Second Edition. Leiton: CRC Press, 2013: 1-16.
[3] MAHASIRIPAN A, TANGTERMSIRIKUL S, SANCHAROEN P. A study of different sacrificial anode materials to protect corrosion of reinforcing steel in concrete[J]. Thammasat International Journal of Science and Technology, 2014, 19: 16-25.
[4] THOMAS S, BIRBILIS N, VENKATRAMAN M S, et al. Corrosion of zinc as a function of pH[J]. CORROSION, 2012, 68(1): 1-9.
[5] KONG G, CHEN J L, LU J T. Effects of pH value of saturated Ca(OH)2 solution on CaHZn coating of hot dip galvanized steel[J]. Journal of Materials Engineering, 2010, 38(9): 74-79 (in Chinese).
[6] TROCONIS DE RINCN O, TORRES-ACOSTA A, SAGS A, et al. Galvanic anodes for reinforced concrete structures: a review[J]. Corrosion, 2018, 74(6): 715-723.
[7] KHOMWAN N, MUNGSANTISUK P. Startup Thailand: a new innovative sacrificial anode for reinforced concrete structures[J]. Engineering Journal, 2019, 23(4): 235-261.
[8] BULLARD S J, CRAMER S, COVINO B. Effectiveness of cathodic protection: final report, June 30, 2009[R]. National Energy Technology Laboratory, 2009.
[9] ZHANG X G. Corrosion and electrochemistry of zinc[M]. New York: Plenum Press, 1996.
[10] WANG F, XU J X, XU Y, et al. A comparative investigation on cathodic protections of three sacrificial anodes on chloride-contaminated reinforced concrete[J]. Construction and Building Materials, 2020, 246: 118476.
[11] GARNICA-RODRGUEZ A, MONTOYA R, RODRGUEZ-GOMEZ F J, et al. Effect of a fast potential change on the early stage of zinc passivation in a saturated calcium hydroxide solution[J]. Frontiers in Materials, 2022, 9: 877728.
[12] Standard test method for determining effects of chemical admixtures on corrosion of embedded steel reinforcement in concrete exposed to chloride environments: ASTM G109[S]. Pennsylvania: American Society of Testing Materials, 2023.
[13] STERN M. Closure to “Discussion of ‘Electrochemical Polarization, 1. A Theoretical Analysis of the Shape of Polarization Curves’ [M. Stern and A. L. Geary (pp. 56-63, Vol. 104)]”[J]. Journal of the Electrochemical Society, 1957, 104(12): 751.
[14] SCULLY J. The polarization resistance method for determination of instantaneous corrosion rates[M]//Electrochemical Techniques in Corrosion Science and Engineering. Leiton: CRC Press, 2002.
[15] CHEN W, DU R G, YE C Q, et al. Study on the corrosion behavior of reinforcing steel in simulated concrete pore solutions using in situ raman spectroscopy assisted by electrochemical techniques[J]. Electrochimica Acta, 2010, 55(20): 5677-5682.
[16] KOLEVA D A. Corrosion and protection in reinforced concrete: pulse cathodic protection: an improved cost-effective alternative[D]. Delft: TU Delft, 2007.
[17] YU Y Z, WANG Y Z, LI J, et al. In situ click-assembling monolayers on copper surface with enhanced corrosion resistance[J]. Corrosion Science, 2016, 113: 133-144.
[18] FAWCETT T G, KABEKKODU S N, BLANTON J R, et al. Chemical analysis by diffraction: the powder diffraction fileTM[J]. Powder Diffraction, 2017, 32(2): 63-71.
[19] MACAS A, ANDRADE C. Corrosion rate of galvanized steel immersed in saturated solutions of Ca(OH)2 in the pH range 12-13.8[J]. British Corrosion Journal, 1983, 18(2): 82-87.
[20] MACAS A, ANDRADE C. Corrosion of galvanized steel in dilute Ca(OH)2 solutions (pH 11.1-12.6)[J]. British Corrosion Journal, 1987, 22(3): 162-171.