• Acta Photonica Sinica
  • Vol. 46, Issue 5, 512001 (2017)
ZHANG Xu1、2、* and ZHOU Tao1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/gzxb20174605.0512001 Cite this Article
    ZHANG Xu, ZHOU Tao. Center Detection Algorithm and Knife Plane Calibration of Flat Top Line Structured Light[J]. Acta Photonica Sinica, 2017, 46(5): 512001 Copy Citation Text show less
    References

    [1] LI Guan-nan, TAN Qing-chang, KOU Ying, et al. A new method for calibrating line strured light 3D measurement model[J]. Acta Photonica Sinica, 2013, 42(11):1334-1339.

    [2] HONG Lei, TIAN Qi-liang, JI Bao-jian. Calibration method for line strured light parameters based on homography matrix[J]. Acta Photonica Sinica,2015, 44(12): 1212003.

    [3] XIONG Sheng-jun,ZHAO Fei,ZHAO Heng,et al.Three-dimensional shape measurement systtem based on auto-synchronous scanners with line strured light[J]. Acta Photonica Sinica,2014,43(11): 1112004.

    [4] NIOAL V, ROSSI C, SAVINO S, et al. A method for the calibration of a 3-D laser scanner[J]. Robotics and Computer- Integrated Manufacturing, 2011, 27(2): 479-484.

    [5] VILACA J, FONSECA J C, PINHO A M. Calibration procedure for 3D Measurement systems using two cameras and laser line[J]. Optics & Laser Technology,2009,41(2):112-119.

    [6] DEWAR R. Self-generated targets for spatial calibration of structured light optical sectioning sensors with respect to an external coordinate systems[C]. Proceeding of Robots and Vision ,1988:5-13.

    [7] JAMES K W. Noncontact machine vision metrology within a CAD coordinate System[C]. Proceeding of Autofact, 1988:9-17.

    [8] ZHAO Y, CHEN X. The circular points-based camera self- calibration study on three classification Algorithms[J]. Journal of Computational Information Systems,2011,7(4):1140-1147.

    [9] HU Z X,WANG Y B,YANG J W, et al. A novel calibration method for three-dimensional modeling system used in virtual maintenance[C].Proceeding of Advanced Computer Control, 2010,5: 301- 303.

    [10] LV Z H,ZHANG Z Y. Build 3D scanner system based on binocular stereo vision[J]. Journal of Computer,2012,7(2):399-404.

    [11] OHTSU N. A threshold selection method from gray-level histo-grams[J]. IEEE Transactions on Systems Man & Cybernetics, 1979, 9(1):62-66.

    [12] ZHANG T Y,SUEN C Y.A fast parallel algorithm for thinning digital patterns[J].Communications of the ACM,1984,27(3):236-239.

    [13] ZHOU Fu-qiang, WANG Fei, ZHANG Guang-jun. Three-step extraction method for line-stripe in structuered light vision[J]. Chinese Journal of Mechanical Engineering, 2008,44(11):215-219.

    [14] SUN Q, CHEN J, LI C. A robust method to extract a laser stripe centre based on grey level moment[J]. Optics and Lasers in Engineering, 2015, 67: 122-127.

    [15] ZHANG Z. A flexible new technique for camera calibration[J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2000, 22(11): 1330-1334.

    [16] MORE J J. The Levenberg-Marquardt algorithm: implementation and theory[M]. Numerical analysis. Springer Berlin Heidelberg, 1978: 105-116.

    [17] SUN Q C, HOU Y Q, TAN Q C, et al. A fast and robust detection algorithm for extraction of the centre of a structured light stripe[J]. Lasers in Engineering, 2015, 31:41-51.

    [18] SUN Q, HOU Y, TAN Q, et al. A robust edge detection method with sub-pixel accuracy[J]. Optik-International Journal for Light and Electron Optics, 2014, 125(14): 3449-3453.

    [19] USAMENTIAGA R, MOLLEDA J, GARCIA D F. Fast and robust laser stripe extraction for 3D reconstruction in industrial environments[J]. Machine Vision and Applications, 2012, 23(1): 179-196.

    ZHANG Xu, ZHOU Tao. Center Detection Algorithm and Knife Plane Calibration of Flat Top Line Structured Light[J]. Acta Photonica Sinica, 2017, 46(5): 512001
    Download Citation