• Chinese Journal of Lasers
  • Vol. 45, Issue 9, 911007 (2018)
Ma Weiguang1、2, Zhou Yueting1、2, Zhao Gang1、2, Jia Mengyuan1、2, Liu Jianxin1、2, Guo Songjie1、2, Dong Lei1、2, Zhang Lei1、2, Yin Wangbao1、2, Xiao Liantuan1、2, Axner Ove3, and Jia Suotang1、2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3Department of Physics, Ume University, Ume Sweden, SE-901 87
  • show less
    DOI: 10.3788/CJL201845.0911007 Cite this Article Set citation alerts
    Ma Weiguang, Zhou Yueting, Zhao Gang, Jia Mengyuan, Liu Jianxin, Guo Songjie, Dong Lei, Zhang Lei, Yin Wangbao, Xiao Liantuan, Axner Ove, Jia Suotang. Review on Noise Immune Cavity Enhanced Optical Heterodyne Molecular Spectroscopy[J]. Chinese Journal of Lasers, 2018, 45(9): 911007 Copy Citation Text show less
    (a) Principle of NICE-OHMS; relationship of laser components and cavity modes when cavity is (b) empty or (c) filled with targeted gas
    Fig. 1. (a) Principle of NICE-OHMS; relationship of laser components and cavity modes when cavity is (b) empty or (c) filled with targeted gas
    Experimental setup of NICE-OHMS based on EDFL
    Fig. 2. Experimental setup of NICE-OHMS based on EDFL
    Doppler broadened (a) absorption and (b) dispersion NICE-OHMS signals
    Fig. 3. Doppler broadened (a) absorption and (b) dispersion NICE-OHMS signals
    Development of detection sensitivity based on Doppler broadened NICE-OHMS
    Fig. 4. Development of detection sensitivity based on Doppler broadened NICE-OHMS
    Effects of same loss and different precision on NICE-OHMS signal
    Fig. 5. Effects of same loss and different precision on NICE-OHMS signal
    (a) CEAS and (b) NICE-OHMS signals with frequency locking by controlling PZT; (c) CEAS and (d) NICE-OHMS signals with frequency locking by controlling combination of PZT and AOM
    Fig. 6. (a) CEAS and (b) NICE-OHMS signals with frequency locking by controlling PZT; (c) CEAS and (d) NICE-OHMS signals with frequency locking by controlling combination of PZT and AOM
    Schematic of (a) differential and (b) balanced detected NICE-OHMS
    Fig. 7. Schematic of (a) differential and (b) balanced detected NICE-OHMS
    ReferenceLaserFinesseWavelength /nmTargeted gasDetectionSensitivity /cm-1Detection mode
    Ref. [40] 1996Nd∶YAG93001064C2HD1.8×10-12sD
    Ref. [16] 1998Nd∶YAG1000001064C2HD1.4×10-14sD
    Ref.[28] 1999Ti∶sapphire17000790C2HD1.4×10-14sD
    Ref. [33] 1999ECDL3001660CH49.5×10-11sD
    Ref. [12] 1999ECDL6000763O23.8×10-11DB
    Ref.[41] 2002Ti∶sapphire16400818C2H26×10-12DB
    Ref.[34] 2004QCL24158518N2O9.7×10-11DB
    Ref. [42] 2004ECDL11000771O27×10-12DB
    Ref.[43] 2006Ti∶sapphire20700797NO2×10-10DB
    Ref.[44] 2007EDFL48001531C2H28×10-11DB/sD
    Ref.[22] 2009ECDL26001513CH42×10-11DB
    Ref.[36] 2010DFB4601551C2H22×10-10DB
    Ref. [20] 2010Ti∶sapphire300924N2+DB
    Ref.[45] 2012ECDL48001510HO21.8×10-9DB
    Ref.[35] 2012DFG3002800-4800CH42×10-7DB
    Ref. [38] 2014OPO1503200-3900HeH+, H3+,HCO+ CH5+DB
    Ref.[21] 2015ECDL16001529CH4,C2H2,HCN4.6×10-8DB
    Ref.[23] 2015QD-ECDL89701283N2O6×10-9DB
    Ref.[46] 2015ECDL185001400HD9.2×10-9sD
    Ref.[18] 2015EDFL550001531C2H22.2×10-13DB
    Ref.[47] 2016OPO1303100HNO+1×10-9DB
    Ref.[39] 2017WGM550001536C2H2, CO26.6×10-14DB
    Ref.[37] 2017DFB1690001532CH41×10-10DB
    Ref.[48] 2017EDFL550001531C2H24.7×10-14DB
    Ref.[19] 2018EDFL550001531C2H22.2×10-14DB
    Table 1. Some important parameters of NICE-OHMS performed by research groups so far
    Ma Weiguang, Zhou Yueting, Zhao Gang, Jia Mengyuan, Liu Jianxin, Guo Songjie, Dong Lei, Zhang Lei, Yin Wangbao, Xiao Liantuan, Axner Ove, Jia Suotang. Review on Noise Immune Cavity Enhanced Optical Heterodyne Molecular Spectroscopy[J]. Chinese Journal of Lasers, 2018, 45(9): 911007
    Download Citation