• NUCLEAR TECHNIQUES
  • Vol. 45, Issue 10, 100403 (2022)
Minjuan QIAO1、2、*, Yi REN1、2, Jianfei WANG1, Di WANG1、2, Jing ZHANG1、2, Yuehong JING1、2, and Yun LIU1、2
Author Affiliations
  • 1Shanxi Zhongfu Nuclear Instruments Co. Ltd., Taiyuan 030006, China
  • 2China Institute for Radiation Protection, Taiyuan 030006, China
  • show less
    DOI: 10.11889/j.0253-3219.2022.hjs.45.100403 Cite this Article
    Minjuan QIAO, Yi REN, Jianfei WANG, Di WANG, Jing ZHANG, Yuehong JING, Yun LIU. A converyor belt-based small article pollution monitoring instrument and performance test[J]. NUCLEAR TECHNIQUES, 2022, 45(10): 100403 Copy Citation Text show less
    References

    [1] ZHANG Jia, DENG Changming, SONG Chengxin et al. The design of floor contaminant monitor[J]. Nuclear Electronics & Detection Technology, 30, 1111-1114(2010).

    [2] SHEN Xiaoling. The design of conveyor belt control system based on PLC[J]. Technology Innovation and Application, 86-88(2018).

    [3] DU Xiangyang, RAO Xianming, HAN Shuping et al. GFM-II large area surface monitor for α/β contamination[J]. Nuclear Electronics & Detection Tschnology, 22, 357-359(2002).

    [4] GUO Qiang, REN Yi, GUO Xirong et al. Hardware design of ZF-102S tool contamination monitor[J]. Nuclear Electronics & Detection Technology, 39, 573-577(2019).

    [5] JIN Lei, PENG Yanyan, YAN Linhui. Study on mobile gamma radiation monitoring system[J]. Electronic Technology, 49, 18-19(2020).

    [6] HUANG Bolun, XU Bing. Design of gamma radiation pollution monitoring system for mobile objects[J]. Nuclear Electronics & Detection Technology, 40, 303-308(2020).

    [7] YU Songke, FANG Fang, LIN Yu et al. Design on intelligent node of gamma radiation monitor[J]. Nuclear Electronics & Detection Technology, 35, 1023-1025(2015).

    [8] LIU Piliang, WU Jindong. Design of converyor belt monitoring system based on image processing[J]. The Electrotechnics, 45-47(2021).

    [9] LI Xuefeng, ZHUANG Jianpei, GAO Yan et al. A dynamic tracking algorithm of robot conveyor belt[J]. Machine Tool & Hydraulics, 49, 65-67(2021).

    [11] LI Zhongliang, LI Chen, ZENG Guoqiang. The mobile radiation monitering platform and terminal design[J]. Nuclear Electronics & Detection Technology, 33, 813-815(2013).

    [13] SHANG Jie, YANG Liu, WEI Yingjing et al. The testing and analysis of installed γ personnel surface contamination monitoring assemblies[J]. Nuclear Electronics & Detection Technology, 40, 200-204(2020).

    [14] FENG Mei, TANG Zhihui, WEI Yingjing et al. Performance test and study of channel vehicle radioactivity monitoring system[J]. China Measurement & Test, 47, 193-198(2021).

    [15] WEI Yingjing, MENG Yanjun, KE Haipeng et al. Performance assessment of gamma-ray monitors for radiation protection monitoring in China[J]. Radiation Protection, 34, 162-167(2014).

    Minjuan QIAO, Yi REN, Jianfei WANG, Di WANG, Jing ZHANG, Yuehong JING, Yun LIU. A converyor belt-based small article pollution monitoring instrument and performance test[J]. NUCLEAR TECHNIQUES, 2022, 45(10): 100403
    Download Citation