[1] J Wilkerson, D S Sayres, J B Smith et al. In situ observations of stratospheric HCl using three-mirror integrated cavity output spectroscopy. Atmospheric Measurement Techniques, 14, 3597-3613(2021).
[2] Q X He, C T Zheng, K Y Zheng et al. Off-axis integrated cavity output spectroscopy for real-time methane measurements with an integrated wavelength-tunable light source. Infrared Physics & Technology, 115, 103705(2021).
[3] J C Zhou, W X Zhao, Y Zhang et al. Amplitude-modulated cavity-enhanced absorption spectroscopy with phase-sensitive detection: A new approach applied to the fast and sensitive detection of NO2. Analytical Chemistry, 94, 3368-3375(2022).
[4] L M Reynard, W W Wong, T Noreen. Accuracy and practical considerations for doubly labeled water analysis in nutrition studies using a laser-based isotope instrument (off-axis integrated cavity output spectroscopy). The Journal of Nutrition, 152, 78-85(2022).
[5] X Wang, H G Jansen, H Duin et al. Measurement of δ18O and δ2H of water and ethanol in wine by Off-Axis Integrated Cavity Output Spectroscopy and Isotope Ratio Mass Spectrometry. European Food Research and Technology, 247, 1899-1912(2021).
[6] M Pal, S Bhattacharya, A Maity et al. Exploring triple-isotopic signatures of water in human exhaled breath, gastric fluid, and drinking water using integrated cavity output spectroscopy. Analytical Chemistry, 92, 5717-5723(2020).
[7] F Fourel, C Lécuyer, P Jame et al. Simultaneous δ2H and δ18O analyses of water inclusions in halite with off-axis integrated cavity output spectroscopy. Journal of Mass Spectrometry, 55, e4615(2020).
[8] D Wang, P H Xie, R Z Hu et al. Progress of measurement of atmospheric NO3 radicals. Journal of Atmospheric and Environmental Optics, 10, 102-116(2015).
[9] A Gupta, P J Singh, D Y Gaikwad et al. Instrumentation and signal processing for the detection of heavy water using off axis-integrated cavity output spectroscopy technique. Review of Scientific Instruments, 89, 023110(2018).
[10] C Dyroff. Optimum signal-to-noise ratio in off-axis integrated cavity output spectroscopy. Optics Letters, 36, 1110(2011).
[11] Y Gong, B Li, Y Han. Optical feedback cavity ring-down technique for accurate measurement of ultra-high reflectivity. Applied Physics B, 93, 355-360(2008).
[12] R M Varma, D S Venables, A A Ruth et al. Long optical cavities for open-path monitoring of atmospheric trace gases and aerosol extinction. Applied Optics, 48, B159-B171(2009).
[13] R A Washenfelder, A O Langford, H Fuchs et al. Measurement of glyoxal using an incoherent broadband cavity enhanced absorption spectrometer. Atmospheric Chemistry and Physics, 8, 7779-7793(2008).
[14] X Tian, Y Cao, J J Wang et al. High sensitivity detection of two-component CH4/H2O based on of f-axis cavity enhanced absorption spectroscopy. Spectroscopy and Spectral Analysis, 39, 3078-3083(2019).
[15] L Y Wu, G Z Gao, X Liu et al. Study on the calibration of reflectivity of the cavity mirrors used in cavity enhanced absorption spectroscopy. Spectroscopy and Spectral Analysis, 41, 2945-2949(2021).
[16] Z B Li, H L Ma, Z S Cao et al. High-sensitive off-axis integrated cavity output spectroscopy and its measurement of ambient CO2 at 2 μm. Acta Physica Sinica, 65, 61-67(2016).
[17] S N Mikhailenko, S Kassi, D Mondelain et al. A spectroscopic database for water vapor between 5850 and 8340 cm-1. Journal of Quantitative Spectroscopy Radiative Transfer, 179, 198-216(2016).
[18] A V Nikitin, O M Lyulin, S N Mikhailenko et al. GOSAT-2009 methane spectral line list in the 5550-6236 cm-1 range. Journal of Quantitative Spectroscopy and Radiative Transfer, 111, 2211-2224(2010).
[19] R B Qi, S K He, X T Li et al. Simulation of TDLAS direct absorption based on HITRAN database. Spectroscopy and Spectral Analysis, 35, 172-177(2015).