• Chinese Optics Letters
  • Vol. 18, Issue 12, 123902 (2020)
Shangyuan Li*, Haidong Cao, and Xiaoping Zheng
Author Affiliations
  • Beijing National Research Center for Information Science and Technology, Department of Electronic Engineering, Tsinghua University, Beijing 100084, China
  • show less
    DOI: 10.3788/COL202018.123902 Cite this Article Set citation alerts
    Shangyuan Li, Haidong Cao, Xiaoping Zheng. Concurrent photonic measurement of angle-of-arrival and chirp rate of microwave LFM signal[J]. Chinese Optics Letters, 2020, 18(12): 123902 Copy Citation Text show less
    Scheme diagram of the proposed approach.
    Fig. 1. Scheme diagram of the proposed approach.
    Frequency-time two-dimensional (2D) image to illustrate the intrinsic feature of an LFM signal, and the dual-frequency generation using AMZI for concurrent measurement of TDOA and chirp rate.
    Fig. 2. Frequency-time two-dimensional (2D) image to illustrate the intrinsic feature of an LFM signal, and the dual-frequency generation using AMZI for concurrent measurement of TDOA and chirp rate.
    Diagram of the whole measurement system.
    Fig. 3. Diagram of the whole measurement system.
    Waveform and spectrum of the measured signal at different SNRs. (a) Waveform with SNR=9.6 dB shows the beating of two sinusoidal signals; (b) spectrum with SNR=9.6 dB shows two frequency peaks; (c) waveform with SNR=−10.4 dB shows nothing but noise in the retrieved signal; (d) spectrum with SNR=−10.4 dB is still able to reveal two frequency components.
    Fig. 4. Waveform and spectrum of the measured signal at different SNRs. (a) Waveform with SNR=9.6dB shows the beating of two sinusoidal signals; (b) spectrum with SNR=9.6dB shows two frequency peaks; (c) waveform with SNR=10.4dB shows nothing but noise in the retrieved signal; (d) spectrum with SNR=10.4dB is still able to reveal two frequency components.
    Measured chirp rate versus SNR.
    Fig. 5. Measured chirp rate versus SNR.
    Measured two-tone spectrum at different time delays.
    Fig. 6. Measured two-tone spectrum at different time delays.
    AOA measurement results and their measurement error at different SNRs. (a) AOA measurement results and (b) measurement error with SNR=9.6 dB. (c) AOA measurement results and (b) measurement error with SNR=−10.4 dB.
    Fig. 7. AOA measurement results and their measurement error at different SNRs. (a) AOA measurement results and (b) measurement error with SNR=9.6dB. (c) AOA measurement results and (b) measurement error with SNR=10.4dB.
    Shangyuan Li, Haidong Cao, Xiaoping Zheng. Concurrent photonic measurement of angle-of-arrival and chirp rate of microwave LFM signal[J]. Chinese Optics Letters, 2020, 18(12): 123902
    Download Citation