• Collection Of theses on high power laser and plasma physics
  • Vol. 13, Issue 1, 96210 (2015)
Yongzhong Wu1,2 and Jianqiang Zhu1
Author Affiliations
  • 1National Laboratory on High Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    DOI: 10.1117/12.2190087 Cite this Article
    Yongzhong Wu, Jianqiang Zhu. Research on Gain Uniformity of Laser Non-imaging Rod Amplifier[J]. Collection Of theses on high power laser and plasma physics, 2015, 13(1): 96210 Copy Citation Text show less

    Abstract

    According to the problem of gain medium cross section high illumination and non-uniformity, which is caused by the laser rod amplifier non-imaging pump style. Orthogonal test design method is used to research the effect of absorption coefficient, gain medium radius, number of xenon lamps, center distance of xenon lamps and gain medium on gain uniformity. The rod amplifier which is made up by the above four elements, its gain medium cross section illumination distribution is simulated by ASAP. The results show that center distance of xenon lamps and gain medium, number of xenon lamps have very little influence on the gain uniformity. When absorption coefficient equal to 5.1 cm-1, gain uniformity will reach the optimum. Under the circumstance of other three elements are equal, the bigger is the gain radius, the smaller slope reflection curve, and the better gain uniformity.