• Acta Physica Sinica
  • Vol. 69, Issue 10, 107801-1 (2020)
Meng-lin Qiu1, Guo-qiang Zhao1, Ting-shun Wang1, Chang-wei Luo1, Guang-fu Wang1、2、*, Feng-shou Zhang1、2, Sha-sha Lv1, and Bin Liao1
Author Affiliations
  • 1Key Laboratory of beam technology of Ministry of Education, College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875, China
  • 2Beijing Radiation Center, Beijing 100875, China
  • show less
    DOI: 10.7498/aps.69.20200020 Cite this Article
    Meng-lin Qiu, Guo-qiang Zhao, Ting-shun Wang, Chang-wei Luo, Guang-fu Wang, Feng-shou Zhang, Sha-sha Lv, Bin Liao. In situ luminescence measurement from lithium fluoride under various ions[J]. Acta Physica Sinica, 2020, 69(10): 107801-1 Copy Citation Text show less
    Schematic of the IBIL experimental setup on BNU400 ion implanter
    Fig. 1. Schematic of the IBIL experimental setup on BNU400 ion implanter
    SRIM calculation of 100 keV H+, He+ and O+ stopping power in lithium fluoride
    Fig. 2. SRIM calculation of 100 keV H+, He+ and O+ stopping power in lithium fluoride
    Emission intensity as function of both fluence and wavelength obtained under 100 keV H+
    Fig. 3. Emission intensity as function of both fluence and wavelength obtained under 100 keV H+
    Evolutions of the luminescence peak intensities at 296, 340, 400 nm with the irradiation fluence under 100 keV H+
    Fig. 4. Evolutions of the luminescence peak intensities at 296, 340, 400 nm with the irradiation fluence under 100 keV H+
    Evolutions of the luminescence peak intensities at 540, 670, 880 nm with the irradiation fluence under 100 keV H+
    Fig. 5. Evolutions of the luminescence peak intensities at 540, 670, 880 nm with the irradiation fluence under 100 keV H+
    Evolutions of the luminescence peak intensities at 296, 340, 400 nm with the irradiation fluence under 100 keV He+
    Fig. 6. Evolutions of the luminescence peak intensities at 296, 340, 400 nm with the irradiation fluence under 100 keV He+
    Evolutions of the luminescence peak intensities at 540, 670, 880 nm with the irradiation fluence under 100 keV He+
    Fig. 7. Evolutions of the luminescence peak intensities at 540, 670, 880 nm with the irradiation fluence under 100 keV He+
    Evolutions of the luminescence peak intensities at 296, 340, 400 nm with the irradiation fluence under 100 keV O+
    Fig. 8. Evolutions of the luminescence peak intensities at 296, 340, 400 nm with the irradiation fluence under 100 keV O+
    Evolutions of the luminescence peak intensities at 540, 670, 880 nm with the irradiation fluence under 100 keV O+
    Fig. 9. Evolutions of the luminescence peak intensities at 540, 670, 880 nm with the irradiation fluence under 100 keV O+
    离子种类$ \rm F_3^{-} $色心 Φmax/cm–2F2色心 Φmax/cm–2$ \rm F_3^{-}/F_2^+ $色心 Φmax/cm–2Se/eV·Å–1Sn/eV·Å–1Rp/μm
    H+10 × 101311.5 × 101324.3 × 101313.920.02320.8336
    He+5 × 10133.3 × 10139.5 × 101321.040.30040.6708
    O+3.8 × 10133 × 10135.9 × 101325.6410.150.2459
    Table 1.

    Comparisons of lithium fluoride under 100 keV H+, He+ and O+

    100 keV的H+、He+和O+3种离子辐照氟化锂材料的结果对比

    Meng-lin Qiu, Guo-qiang Zhao, Ting-shun Wang, Chang-wei Luo, Guang-fu Wang, Feng-shou Zhang, Sha-sha Lv, Bin Liao. In situ luminescence measurement from lithium fluoride under various ions[J]. Acta Physica Sinica, 2020, 69(10): 107801-1
    Download Citation