[2] YE SH X. Photoelectric displacement measurement technology [M].Chengdu: Sichuan Technology Press, 2003.(in Chinese)
[3] DONG J, WAN Q H, ZHAO CH H, et al.. Current situation and prospect of fault diagnosis for photoelectric encoder [J].Chinese Optics, 2015, 10(8): 757-765.(in Chinese)
[4] XIAO S SH, LAN Z M, ZHAO Y Q. Effect of Shaft eccentricity on measurement signal of optical encoder [J].Opto-Electronic Engineering, 2007, 10(34): 67-68.(in Chinese)
[5] LI H, FENG CH Y, DING L H. Dynamic evaluation method for interpolation errors in photoelectric encoder [J]. Chinese Journal of Sensors and Actuatours, 2015, 12(4): 928-930.(in Chinese)
[6] HUANG L, PAN N, MA W L, et al. Error analysis and experimentation of scale tape encoder [J].Chinese Optics, 2015, 8(6): 465-469.(in Chinese)
[7] PAN N, MA W L. Error analysis and correction of scale tape grating encoder [J].Chinese Optics, 2013, 10(6): 789-792.(in Chinese)
[8] YANG W.Research of auto-detection system of photoelectric encoder based on DSP [D].Changchun: Changchun Institute of Optics, Fine mechanics and Physics, Chinese Academy of Sciences, China, 2010, 10.(in Chinese)
[9] DENG F, CHEN J, CHEN W J, et al.. A high precision test method and apparatus for photoelectric encoder [J].Transactions of Beijing Institute Technology, 2007, 11(27): 978-1008.(in Chinese)
[10] SUN SH H, ZHAO CH H, WAN Q H, et al. Automatic detection system for miniature photoelectrical encoder [J]. Chinese Optics, 2013, 6(8): 601-605.(in Chinese)
[11] LI M. Measurement Platform for Photoelectric encoder [D].Changchun: Changchun University of Science and Technology, 2013, 3.(in Chinese)
[12] WATANABE T, FUJIMOTO H, NAKAYAMA K, et al.. Automatic high precision calibration system for encoder [C]. Proceedings of SPICE, 2001, 4401: 267-274.
[13] PALMER E W. Goniometer with continuously rotating gratings for use as angle standard [J].Precision Engineering, 1988, 10(3): 147-152.
[14] YU H, WAN Q H, WANG SH J. Dynamic error analysis of small absolute photoelectric encoder [J].Chinese Laser, 2013, 8(40): 146-150.(in Chinese)
[15] WANG X J. Errors and precision analysis of subdivision signals for photoelectric angle encoders [J].Opt. Precision Eng., 2012, 2(20): 380-385.(in Chinese)
[16] YU H, WAN Q H, WANG SH J, et al.. High-precision real-time angle reference in dynamic measurement of photoelectric encoder[J].Chinese Opitcs, 2015, 8(6): 448-453.
[17] AI CH G, ZHU M, SUN H X. Eccentric testing ofbenchmark circular grating and compensation of angular error [J].Opt. Precision Eng., 2012, 11(20): 2480-2483.(in Chinese)
[18] ZHAO J K, ZHANG ZH F, et al.. Error analysis for measurement of encoder with shaft eccentricity [J].Acta Photonica Sinica, 2007, 6(36): 250-252.(in Chinese)
[19] SHENTU L F, TANG H T, WANG CH X. The influence of membrane stress in the flexible laminated membrane coupling due to shaft misalignment [J].Journal of Strength, 1999, 6(21): 113-116.(in Chinese)